Esprit 728 Ultra & 738 Ultra
29
7.8
Entry Delay 1
Decimal Programming
D
Address 050
Default: 45 seconds
Any zone that has not been identified as either Instant Zones, Follow Zones, Entry Delay 2, or 24Hr and Fire Zones will
automatically default to Delay 1. You can program the Delay 1 period between 001 and 255 seconds into address 050. If a zone
defined as Delay 1 opens in an armed system, the control panel will wait the pre-programmed period of time before generating an
alarm. This provides users with the time required to disarm the system when entering the protected area.
[
ENTER
]
+ Installer code +
[0] [5] [0]
+ 3-digit decimal value (001 to 255) +
[
ENTER
]
7.9
Entry Delay 2
728 Ultra: Feature Select Programming
D
Address 112; Keys
[1]
to
[10 (0)]
738 Ultra: Feature Select Programming
D
Addresses 112 and 114;
Keys
[1]
to
[10 (0)], [
STAY
]/[11]
and
[
FORCE
]/[
AWAY
]/[12]
)
on page 13, select which zones will be defined as Entry Delay 2 Zones. If a zone defined as
Delay 2 opens in an armed system, the control panel will wait for the duration of the Entry Time Delay 2 period (see page 29)
before generating an alarm. This provides users with the time required to disarm the system when entering the protected area.
7.9.1
Entry Time Delay 2
Decimal Programming
D
Address 051
Default: 45 seconds
This applies to all zones defined as Entry Delay 2 (see page 29). You can program the delay between 001 and 255
seconds.
[
ENTER
]
+ Installer code +
[0] [5] [1]
+ 3-digit decimal value (001 to 255) +
[
ENTER
]
7.10
Partitioning
Feature Select Programming
D
Address 086; Key
[8]
Default: Disabled
This feature divides the alarm system into two distinct systems, identified as System A and System B. You can assign each zone
to System A, System B, both systems, or neither system. Partitioning works as follows:
• Zones assigned to System A will arm/disarm when the system is System A Armed/Disarmed.
• Zones assigned to System B will arm/disarm when the system is System B Armed/Disarmed.
• Zones assigned to both systems (dual area) will arm when the system is either System A Armed, System B Armed or when
both systems are armed and will disarm only when both systems disarm.
• Zones not associated with any system (common area) will arm only when the system is both System A Armed and System B
Armed and will only disarm when at least one of the two systems disarms.
For more information on arming or disarming partitions, see
on page 41. Also see
7.10.1
System A/Stay Zones
728 Ultra: Feature Select Programming
D
Address 116; Keys
[1]
to
[10 (0)]
738 Ultra: Feature Select Programming
D
Addresses 116 and 118;
Keys
[1]
to
[10 (0)], [
STAY
]/[11]
and
[
FORCE
]/
[
AWAY
]/[12]
)
on page 13, select which zones will be assigned to System A, or if the system isn’t
partitioned, which zones will be identified as stay zones. For details on System A zones refer to
above. See
on page 41 for more information.
7.10.2
System B Zones
728 Ultra: Feature Select Programming
D
Address 120; Keys
[1]
to
[10 (0)]
738 Ultra: Feature Select Programming
D
Addresses 120 and 122;
Keys
[1]
to
[10 (0)], [
STAY
]/[11]
and
[
FORCE
]/
[
AWAY
]/[12]
)
on page 13, select which zones will be assigned to System B. For details on
System B zones, refer to
7.11
Bypass Enabled Zones
728 Ultra: Feature Select Programming
D
Address 124; Keys
[1]
to
[10 (0)]
738 Ultra: Feature Select Programming
D
Addresses 124 and 126;
Keys
[1]
to
[10 (0)], [
STAY
]/[11]
and
[
FORCE
]/[
AWAY
]/[12]
)
on page 13, select which zones will be defined as bypass enabled. Only zones defined as
bypass enabled can be used for manual zone bypassing (see
on page 42) or during Auto Zone
Shutdown (see page 30).
Bypassed zones can automatically be reported to the monitoring station upon arming (738 Ultra only). Please see
on page 19 for more information.