Esprit 728 Ultra & 738 Ultra
19
6.4
System Account Codes
Streamline - Section 08
D
Hex Programming - Addresses 032 to 035
All report codes are preceded by a 3- or 4-digit system account code to ensure correct identification to the monitoring station,
identifying from which security system the event originated. For example, if a zone opens, the control panel will first send the
account code followed by the appropriate report code. In a partitioned system, the control panel can send a separate account code
for each system. This will identify to the monitoring station from which partition the report code originated. To do so, program a
different number into each account code, where Account code #1 represents System A and Account code #2 represents System B.
If partitioning is disabled, program the same value for both account numbers.
There are no defaults and you can enter any hex digit from 0 to F. Please note, that if required, system account codes can have 3
digits. To do so, press the
[2
ND
]
key followed by the 3-digit account number.
[
ENTER
]
+ Installer code +
[7]
+
[0] [8]
+ 4-digit Account code #1 + 4-digit Account code #2 +
[
ENTER
]
[
ENTER
]
+ Installer code +
[7]
+
[0] [8]
+
[2
ND
]
+ 3-digit Account code #1 +
[2
ND
]
3-digit Account code #2 +
[
ENTER
]
6.5
Communicator Formats
Streamline - Section 09
D
Hex Programming - Address 038
Default: Ademco Slow for both numbers
The following option will determine which format the control panel will use to communicate with the monitoring station. You can
select a different Communicator Format for each Monitoring Station Telephone Number. Using Table 6, select the appropriate
Communicator Format. The first digit represents the Communication Format for Monitoring Station Telephone Number 1
(MSTN1) and the second digit represents the Communication Format for Monitoring Station Telephone Number 2 (MSTN2).
Below you will find a brief description of all available Communicator Formats.
[
ENTER
]
+ Installer code +
[0] [3] [8]
+ First digit = (MSTN1) + Second digit = (MSTN2) +
[
ENTER
]
Table 6: Communicator Formats
6.5.1
Ademco Contact ID (All Codes)
Please note that this format must use a 4-digit system account code (see section 6.4). Ademco Contact ID is a fast
communicator format that uses tone transmission instead of pulse transmission. This communicator format also uses a
pre-defined list of industry standard messages and event codes that should suit most of your basic installation needs.
Using the All Codes format, the control panel will automatically generate the Contact ID event codes (see Table 7) for
every event in addresses 300 to 527. Therefore, you do not need to program addresses 300 to 527.
Bypassed zones can automatically be reported to the monitoring station upon arming (738 Ultra only). If the first and
second digits of Address 038 (Communicator Formats 1 & 2) are both programmed with
[0]
, the next time the system
is armed, the control panel will report to the monitoring station which zone(s) are bypassed.
Table 7: Contact ID Event Codes
Key
Key
[2
ND
]
=
ADEMCO
slow (1400Hz, 1900Hz, 10bps)
[6]
=
RADIONICS
with PARITY (1400Hz, 40Bps)
[1]
= (1400Hz, 1800Hz, 10bps)
[7]
=
RADIONICS
with PARITY (2300Hz, 40Bps)
[2]
=
SILENT KNIGHT
fast (1400Hz, 1900Hz, 20bps)
[8]
=
* ADEMCO
express
[3]
=
SESCOA
(2300Hz, 1800Hz, 20bps)
[9]
=
* ADEMCO
contact ID (programmable codes)
[4]
=
RADIONICS
(40Bps with 1400Hz handshake)
[0]
=
* ADEMCO
contact ID (all codes)
[5]
=
RADIONICS
(40Bps with 2300Hz handshake)
[
TBL
]/[
TRBL
]
=
* PAGER FORMAT
- (personal dialing)
* = 4-digit account codes only
System Event
Event Code Addresses Contact ID Message
Contact ID Code #
Alarms/Restores
400 to 447
Burglary Zone #
130
Alarm/Restore on Zone 3 if 24Hr fire or 2-wire
402, 426
Fire Alarm
110
Alarm/Restore on Zone 5 if 2-wire enabled † (728 Ultra only)
404, 428
Fire Alarm
110
Arm/Disarm
301 to 349 / 351 to 399
Open/Close By User #
401
Zone Shutdown
448 to 471
Burglary Bypass #
573
Zone Tamper
472 to 495
Sensor Tamper
383
Zone Tamper Reset
510
Sensor Tamper
383
Auxiliary Power Trouble
496 and 504
System Trouble
300
Bell Disconnect/Max. Current Trouble
497 and 505
Bell 1 Trouble
321
Low Battery
498 and 506
Low System Battery
302
AC Fail
499 and 507
AC Loss
301
Fire Loop Trouble
500 and 508
Fire Loop Trouble
373
†
If 2-wire smoke with ATZ