14
Reference & Installation Manual
Part 5: Panel Settings for Espload
5.1
Panel Answer Options
Streamline - Section 00
D
Hex Programming - Address 003
Default: Answering Machine Override Disabled; Number of Rings = 08
The following two options will define how the control panels answer an incoming call from a computer using the Espload software.
In order for the Espload software to remotely communicate with the control panel, call the installation site twice using the Espload
Software. To do so, program the first digit in address 003 with any value from 1 to F (see Table 3). This value represents the
length of the delay period the control panel will wait between the first and second call. Using the Espload software, call the
installation site and on the second ring press
[
ENTER
]
on the keyboard to hang-up. After hanging up, the Espload software will
wait 10 seconds before calling the installation site back. If the installation site is called back within the programmed delay period,
the control panel will override the answering machine or service by picking up on the first ring. To disable this option program
[2
ND
]
or
[1]
as the first digit in address 003.
Example: A security installation is using an answering machine set to answer after 3 rings, the first digit at address 003 has been
programmed with 5 (40 sec.) and the second digit has been programmed with 8. When you call the installation site with the
Espload software the first time, wait two rings and press
[
ENTER
]
on the keyboard. The Espload software will wait 10 seconds
before calling the installation site back. If the second call is made within 40 seconds, the panel will pick up the line on the first ring.
If it takes more than 40 seconds, the panel will not answer on the first ring and the answering machine will answer after three rings.
[
ENTER
]
+ Installer code +
[0] [0] [3]
+ 1st digit + 2nd digit (01 to 15 rings) +
[
ENTER
]
The second digit represents the number of rings the control panel will wait before picking up the line. If the line is not answered
after the number of re-programmed rings, the control panel will answer the call. Note the control panel resets the ring counter
every 64 seconds. Therefore, if someone or an answering machine answers a call before the number of pre-programmed rings
has elapsed, the control panel will keep the number of rings in memory for 64 seconds. If you hang-up and call the installation site
back within 64 seconds, the control panel will continue to count the number of rings from the first call. After reaching the total
number of rings, the control panel will answer the call. The number of rings can be set from 1 to 15 by programming the second
digit at address 003 with any hex-digit from 1 to F. Program the second digit with
[2
ND
]
to disable this option.
Example: Address 003 =
[2
ND
]
[8]
. Using the Espload software, you call an installation site where there is no answering machine
or service and no one is home. Since there is no one to answer the telephone call, the control panel will pick-up the line on the
eighth ring. If someone happens to be home and answers the telephone after three rings, the control panel will keep the three
rings in memory for 64 seconds. If you hang-up and call back the installation site within 64 seconds the control panel will answer
the call on the fifth ring. If you call back after 64 seconds the ring counter will have been reset and the control panel will answer
the call on the eighth ring.
If you program four rings or less, the control panel will always reset the “ring” counter.
5.2
Panel Identifier
Streamline - Section 01
D
Hex Programming - Addresses 004 and 005
This four-digit code identifies the control panel to the Espload software before initiating upload. Program the same 4-digit code
into the control panel and the Espload software before attempting to establish communication. If the codes do not match, the
control panel will not establish communication. Enter any hex digits from 0 to F.
[
ENTER
]
+ Installer code +
[0] [0] [4]
+ First 2
[0] [0] [5]
+ Final 2
[
ENTER
]
5.3
PC Password
Streamline - Section 01
D
Hex Programming - Addresses 006 and 007
This four-digit download password identifies the PC to the panel, before beginning the download process. Enter the same
password into the Espload software and the control panel. If the passwords are not the same, Espload will not establish
communication. Enter any hex digits from 0 to F.
[
ENTER
]
+ Installer code +
[0] [0] [6]
+ First 2
[0] [0] [7]
+ Final 2
[
ENTER
]
Table 3: Answering Machine Override Options
[2
ND
]
or
[1]
= Answering Machine Override disabled
[2]
= 16 seconds
[4]
= 32 seconds
[6]
= 48 seconds
[8]
to
[
F
]
= 60 seconds
[3]
= 24 seconds
[5]
= 40 seconds
[7]
= 56 seconds