Esprit 728 Ultra & 738 Ultra
1
Part 1: Introduction
1.1
About This Manual
This manual provides all the information you will need to understand panel operation, features and functions. If you are familiar
with other security control panels, we recommend that you read this manual at least once to familiarize yourself with panel
features and programming. Please refer to the index for a complete list of this manual's contents.
1.2
New Features
1.3
Main Features
• 4 zone inputs (8 zones with ATZ) + 2 keypad zones (728 Ultra)
• 8 zone inputs (16 zones with ATZ) + 2 keypad zones (738 Ultra)
• 2 partitions
• 49 user codes
• 256 event buffer
• 1 PGM output for 728 Ultra and 2 PGM outputs for 738 Ultra (50mA transistor output)
• 1.1A switching power supply
• 1 supervised auxiliary output (728 Ultra: 450mA, fuseless shutdown at 650mA; 738 Ultra: 500mA, fuseless shutdown at 700mA)
• 1 supervised bell output (fuseless shutdown at 3A)
• 1 supervised telephone line (supports Ademco Contact ID, Pager and slow report formats)
• CTR-21 approved dialer
• On-board connectors for backup battery and serial port
• Compatible with all Esprit keypads
1.4
Specifications
• AC power:
16.5Vac transformer with minimum 20VA rating (40VA recommended), 50-60Hz
• Battery:
12Vdc, 4Ah/7Ah†
• Aux. power:
450mA, fuseless shutdown at 650mA for 728 Ultra; 500mA, fuseless shutdown at 700mA for 738 Ultra)†
• Bell output:
1A (fuseless shutdown at 3A)
• PGM outputs:
One 50mA PGM transistor output (728 Ultra); Two 50mA PGM transistor output (738 Ultra)
• Serial data output:
(1200, 1, N) for use with accessory modules (not for use with UL systems)
on page 45 for UL Specifications. Specifications may change without prior notice.
Feature
728 Ultra
V4.10
728 Ultra
V4.20 - 4.40
738 Ultra
V4.0
738 Ultra V4.1
2-wire smoke detector
9
9
9
Serial or parallel wiring for ATZ connections (see page 27)
9
9
9
9
Master Code Lock (see page 11)
9
9
9
9
New Pager reporting options: Pager Delay, Pager Format Options and
Pager Report Event Options (page 21)
9
9
9
9
Closing Delinquency Timer and Time options (see page 34)
9
9
9
9
Auto Test Report Time Option (see page 23)
9
9
9
9
Restrict Arming on Battery Failure (see page 34) and Restrict Arming on
Tamper Trouble (see page 34)
9
9
9
9
New on-board green
STATUS
LED (see page 11)
9
9
9
9
Timed Test Transmission (see page 24)
9
9
Bypassed zones reported to monitoring station on arming (see page 19)
9
6.15
Report Zone Restore Options
Feature Select Programming
D
Address 088; Key
[
BYP
]
Default: Zone Restore Codes Transmit on Bell Cut-Off
With the
[
BYP
]
key OFF, the report codes programmed at addresses 424 to 447 (see
on page 22) will only
transmit if the zone has returned to normal after bell cut-off (see
on page 34). With the
[
BYP
]
key ON, the
codes will transmit as soon as the zone returns to normal (zone closure).
Key
[
BYP
]
OFF: Report on Bell Cut-Off
Key
[
BYP
]
ON: Report on Zone Closure
[
ENTER
]
+ Installer code +
[0] [8] [8]
+
[
BYP
]
ON/OFF +
[
ENTER
]
Section #
Programming method used to program
this feature
Section title
Where the feature is
programmed
Factory default
Description of feature
How to program
Option
Содержание ESPRIT 728 ULT
Страница 1: ...Versions 4 4 728ULT 4 1 738ULT Reference Installation Manual 728ULT 738ULT ...
Страница 2: ......
Страница 54: ...Notes ...
Страница 55: ......