Reference & Installation Manual
Address 090 Key
[3]
ON:
The time programmed in address 046 is changed from days to hours and address 047 will be ignored.
The Auto Test report will be transmitted after the number of hours programmed at address 046 and the minutes programmed at
address 048 have elapsed.
Example: 002 and 030 are programmed at addresses 046 and 048 respectively. With address 090 key
[3]
ON, the Auto Test
report will be transmitted at the 30th minute of every 2nd hour.
6.11
Timed Test Transmission (738 Ultra only)
Decimal Programming
D
Address 046
Enabling the Timed Test Transmission allows the control panel to send a test transmission when the system is armed or
disarmed, depending on the data entered in addresses 047 and 048. The Event code is programmed at address 512.
[
ENTER
]
+ Installer code +
[0] [4] [6]
+
[2] [5] [5]
+
[
ENTER
]
When the system is armed, the control panel transmits the test report code at regular intervals while the partition is armed.
Program the number of minutes (001 to 255; default: disabled (000)) between each transmission in address 047.
[
ENTER
]
+ Installer code +
[0] [4] [7]
+ 3-digit decimal value (001 to 255) +
[
ENTER
]
When the system is disarmed, the control panel transmits the test report code at regular intervals while the partition is disarmed.
Program the number of minutes (001 to 255; default: disabled (000)) between each transmission in address 048.
[
ENTER
]
+ Installer code +
[0] [4] [8]
+ 3-digit decimal value (001 to 255) +
[
ENTER
]
6.12
Manual Test Report
Key Access Programming
D
Key
[
BYP
]
Activating the manual test report will send the Event code programmed at address 512 to the monitoring station.
[
ENTER
]
+ (Installer, Master or User code 1) +
[
BYP
]
+
[
ENTER
]
6.13
Power Failure Report Delay
Decimal Programming
D
Address 054
Default: 30 minutes
After a power failure, the control panel will delay transmission of the event code programmed at address 499 by the length of time
programmed at this address (001 to 255 minutes).
[
ENTER
]
+ Installer code +
[0] [5] [4]
+ 3-digit decimal value (001 to 255) +
[
ENTER
]
6.14
Recent Close Delay
Decimal Programming
D
Address 060
Default: Recent Close Delay Disabled
The system will transmit the recent close event code programmed at address 519 if after arming the system, an alarm occurs
within the period programmed at this address (001 to 255 minutes). Program 000 into address 060 to disable this feature.
[
ENTER
]
+ Installer code +
[0] [6] [0]
+ 3-digit decimal value (001 to 255) +
[
ENTER
]
6.15
Report Zone Restore Options
Feature Select Programming
D
Address 088; Key
[
BYP
]
Default: Zone Restore Codes Transmit on Bell Cut-Off
With the
[
BYP
]
key OFF, the report codes programmed at addresses 424 to 447 (see
on page 22) will only
transmit if the zone has returned to normal after bell cut-off (see
on page 34). With the
[
BYP
]
key ON, the codes
will transmit as soon as the zone returns to normal (zone closure).
Key
[
BYP
]
OFF: Report on Bell Cut-Off
Key
[
BYP
]
ON: Report on Zone Closure
[
ENTER
]
+ Installer code +
[0] [8] [8]
+
[
BYP
]
ON/OFF +
[
ENTER
]
6.16
Report Code Disarming Options
Feature Select Programming
D
Address 088; Key
[
TBL
]/[
TRBL
]
Default: Disarming Codes Transmit on User Disarming
With the
[
TBL
]/[
TRBL
]
key OFF, the Disarming codes programmed at addresses 350 to 399 (see
will transmit whenever a user disarms the system. With the
[
TBL
]/[
TRBL
]
key ON, the control panel will transmit these codes when
a user disarms a system in alarm.
Key
[
TBL
]
OFF: Always Report Disarm
Key
[
TBL
]
ON: Report Disarm Only After Alarm
[
ENTER
]
+ Installer code +
[0] [8] [8]
+
[
TBL
]/[
TRBL
]
ON/OFF +
[