Reference & Installation Manual
7.11.1
Auto Zone Shutdown
Feature Select Programming
D
Address 086; Key
[
TBL
]
or
[
TRBL
]
Default: Auto Zone Shutdown Disabled
The control panel will automatically bypass any bypass enabled zones which initiate 5 consecutive alarms in the same-
armed period. Therefore, the zone will no longer generate an alarm. After the control panel has bypassed a zone, it will
report an event code to the monitoring station if programmed at addresses 448 to 457 (728 Ultra) or 465 (738 Ultra).
The Auto Zone Shutdown counter resets when the system is disarmed.
This feature is also a function of the
on page 24. If this option is set for report zone
restore on bell cut-off, the zone will only be bypassed after the bell or siren has cut off 5 consecutive times in the same
armed period. While if the option is set for report zone on zone closure, the zone will be bypassed when the zone has
opened and closed 5 consecutive times in one armed period.
Key
[
TBL
]/[
TRBL
]
OFF: Auto Zone Shutdown Disabled
Key
[
TBL
]/[
TRBL
]
ON: Auto Zone Shutdown Enabled
[
ENTER
]
+ Installer code +
[0] [8] [6]
+
[
TBL
]/[
TRBL
]
ON/OFF +
[
ENTER
]
7.12
EOL Zones (Enabled/Disabled)
Feature Select Programming
D
Address 088; Key
[
MEM
]
Default: Enabled (No EOL)
If the system requires the use of 1k
9
end of line resistors on zone input terminals, disable this feature (see
Single Zone Input Terminal Connections
Key
[
MEM
]
OFF: Input Zones use EOL Resistors
Key
[
MEM
]
ON: Input Zones do not use EOL Resistors
[
ENTER
]
+ Installer code +
[0] [8] [8]
+
[
MEM
]
ON/OFF +
[
ENTER
]
7.13
Keypad Zone 1 Supervision
Feature Select Programming
D
Address 090; Key
[
STAY
]
Default: Disabled
When using a keypad defined as Keypad Zone 1, enable this feature. When enabled, the control panel will verify the presence of
a keypad and the keypad zone. For more information see
Key
[
STAY
]
OFF: Keypad Zone 1 Disabled
Key
[
STAY
]
ON: Keypad Zone 1 Enabled
[
ENTER
]
+ Installer code +
[0] [9] [0]
+
[
STAY
]
ON/OFF +
[
ENTER
]
7.14
Keypad Zone 2 Supervision
Feature Select Programming
D
Address 090; Key
[
AWAY
]/[
FORCE
]
Default: Disabled
When using a keypad defined as Keypad Zone 2, enable this feature. When enabled, the control panel will verify for the presence
of a keypad and the keypad zone. For more information see
Key
[
AWAY
]/[
FORCE
]
OFF: Keypad Zone 2 Disabled
Key
[
AWAY
]/[
FORCE
]
ON: Keypad Zone 2 Enabled
[
ENTER
]
+ Installer code +
[0] [9] [0]
+
[
AWAY
]/[
FORCE
]
ON/OFF +
[
ENTER
]