input, a simple crimp-on DB-25 connector may be used, and crimped onto the Projector-Signal-Input
ribbon cable provided with PASS.

J802: Projector-Signal-Output

The Projector-Signal-Output connector on the PASS board should be parsed out into pairs of signals, and
then directed to various components within the projector. The signals and recommended connections are
discussed below. Note that since this is an IDC connector, the pin numbers do not correspond to the ILDA
pin-out on a DB-25. HOWEVER, if you crimp a DB-25-connector onto the output ribbon cable, then the
pins will correspond directly to the ILDA pin-out. This is because the pin designations of a DB-connector
are “in-line” while the pin designations of an IDC connector are “even and odd”.

Pins 1 and 2 correspond to the X+ and X- signal respectively. These should be connected to the
X+ and X- input on the X-axis scanner amplifier.
Pins 3 and 4 correspond to the Y+ and Y- signals respectively. These should be connected to the
Y+ and Y- input on the Y-axis scanner amplifier.

Note: There should NOT be a connection to the “signal ground” of any scanner amplifier. The only
“ground” connection to the scanner amplifier (or amplifiers) should be from the power supply itself.
Connecting to the “signal ground” on a scanner amplifier will introduce a ground loop, which may cause
distorted images. See the “Power and X-Y Position Signal Connections” on the following pages.

Pins 5 and 6 correspond to the Intensity/B and Intensity/Blanking – signals respectively.
These may be used for a single-color projector or projectors that use a PCAOM for color.
Pins 7 and 8 correspond to the Projector Interlock loop pins 4 and 17 from the ILDA connector.
Note that PASS will interrupt this interlock signal loop in the event of a critical fault and
when power is insufficient, therefore it is MANDATORY that projector manufacturers
implement an interlock scheme that makes use of these signals.
 Ideally this interlock loop
should interrupt power to the lasers themselves, thus, in the event of a major problem, PASS can
interrupt power to the lasers. Alternatively the interlock loop may be routed to a SEPARATE shutter
placed just before the X-Y scanners and after the PASS light sensor.
Pins 9 and 10 correspond to Red+ and Red – color signals respectively. These should be
connected to the RED input on a PCAOM driver or directly to a laser diode driver.
Pins 11 and 12 correspond to Green+ and Green – color signals respectively. These should be
connected to the GREEN input on a PCAOM driver or directly to a laser diode driver.
Pins 13 and 14 correspond to Blue+ and Blue – color signals respectively. These should be
connected to the BLUE input on a PCAOM driver or directly to a laser diode driver.
Pins 15 and 16 correspond to Deep Blue+ and Deep Blue – color signals respectively. These are
most often not used by modern RGB laser projectors and thus, can be left unconnected. If they are
used, they should be connected to the DEEP BLUE input on a PCAOM driver or directly to a laser
diode driver.
Pins 17 and 18 correspond to and Yellow – color signals respectively. These are most
often not used by modern RGB laser projectors and thus, can be left unconnected. If they are used,
they should be connected to the YELLOW input on a PCAOM driver or directly to a laser diode
driver.
Pins 19 and 20 correspond to Cyan+ and Cyan – color signals respectively. These are most often
not used by modern RGB laser projectors and thus, can be left unconnected. If they are used, they

Содержание PASS

Страница 1: ...FE LASER EXPOSURE This manual contains important information on how to install PASS in a laser projector how to perform adjustments and how to make sure that the show remains safe including a requirem...

Страница 2: ...levels of redundancy and with circuitry that is designed to fail safe In fact PASS is designed to maintain safety even in the face of several simultaneous failures Although the PASS hardware circuit...

Страница 3: ...intensity outputs PASS will also open the projector interlock signal path ILDA pins 4 and 17 As long as a fast shutter is located within the beam path and as long as the interlock signal path is used...

Страница 4: ...Monitor The Beam Power Monitor is perhaps the most unique and important aspect of PASS The Beam Power Monitor is able to make sure that the light coming out of the projector conforms to what is expec...

Страница 5: ...the PASS logic the color and intensity signals are blanked the shutter is closed and the projector interlock signal path is opened The system will remain in that state until power is recycled or until...

Страница 6: ...CAOM for color Pins 7 and 8 correspond to the Projector Interlock loop pins 4 and 17 from the ILDA connector Note that PASS will interrupt this interlock signal loop in the event of a critical fault a...

Страница 7: ...normal circumstances the state of this signal will correspond directly to pin 13 on an ILDA input connector However in the event of a major fault PASS will forcibly close the shutter using this signal...

Страница 8: ...an external Emergency Stop ESTOP switch such as a pushbutton or red mushroom type switch When this pin is connected to Pin 2 ground ESTOP is activated When Pin 1 is left oating then ESTOP is inactive...

Страница 9: ...or not PASS is ready to be activated armed If this signal is HIGH it indicates that the power supply is OK ESTOP is not activated and light is not detected and thus PASS may be activated by performin...

Страница 10: ...r light detector failure Note that unlike the other LED outputs on the control panel connector the Status LED outputs will latch in the event that a fault is detected They will remain in the latched s...

Страница 11: ...y additional ground wire from each scanner ampli er to the PASS board Doing so would introduce a ground loop which may cause distorted images If you are using a one dual axis scanner ampli er the reco...

Страница 12: ...is moved to the left on the Horizon control is monitored and PASS will only allow static or slow beams above the horizon If there is a slow moving or non moving beam below the horizon it will be exti...

Страница 13: ...red to sweep in X and or Y in order to be considered to be safe At the factory Pangolin sets this to around 5 radians per second Note that the scale of this control in radians per second depends on th...

Страница 14: ...i color LED on the PASS board Also note that the Maximum Safe Beam Power and Minimum Power adjustments are ignored if the switch 4 is turned on see switches on page 20 PASS Adjustment Procedure NOTE T...

Страница 15: ...hen it is in the audience area Once this is done with the slow moving circle COLLAPSE the Y axis change Y size to zero in the software which will project essentially a slow moving horizontal beam cent...

Страница 16: ...terms of Watts Per Square Centimeter also known as irradiance instead of Watts also known as radiant power This is an important concept that must be understood The laser safety standards are based on...

Страница 17: ...til it trips We also recommend that you run a number of test patterns and show program material with the brightness set to the maximum safe power determined above i e 27 If the projector occasionally...

Страница 18: ...e is not overloaded with light and merely delivering a saturated maximum voltage to the oscilloscope as this will arti cially lengthen the pulse width The PDA100A photodiode has an attenuator dial on...

Страница 19: ...as the nal shutter opens faster than around 1 20th of a second Generally the light sensor is fashioned as a glass window that is used to sample the outgoing laser beam at a 45 degree or so angle and d...

Страница 20: ...with the spectral attening lter attached and logarithmic ampli er board is the model SEL033 detector with model F at response ler and model A430 ampli er all available from International Light Techno...

Страница 21: ...g with the other projector features for example no doubt including a lens installed either inside or outside the laser projector to increase divergence to help ensure audience safety Finally the audie...

Страница 22: ...stments on PASS must be con gured properly for the scanning velocity and dwell time as well as the projection horizon if used Moreover the light sensor related adjustments on PASS must be con gured to...

Страница 23: ...2022 07 28 09 15 23 26 PASS Complete Help Docs https wiki pangolin com Dimensions and mounting holes...

Страница 24: ...m PASS This Agreement provides you with the authorization to use PASS subject to the terms and conditions herein If you do not agree to all the terms and conditions of this Agreement do not use PASS I...

Страница 25: ...Pangolin without Pangolin s prior written consent AGREEMENT LENGTH AND TERMINATION PROCEDURE This Agreement is e ective until terminated 4 You may terminate this Agreement at any time by sending writt...

Страница 26: ...owing deposit with the mail carrier for all other allowable forms of notice ENTIRE AGREEMENT This Agreement constitutes the entire agreement with respect to the use of 11 PASS and supersedes all prior...

Отзывы: