2022/07/28 09:15
11/26
PASS
Complete Help Docs - https://wiki.pangolin.com/
below:
Note that each scanner amplifier, as well as the PASS circuit board itself must each have their own power
wires going back to the power supply. These wires should all meet at the power supply itself. If you have
two power supplies (one for +24V and the other for –24V) then these power supplies should establish a
central connection where all wires meet. This is called a “single-point grounding scheme. Wiring the
power supply in any other way will cause a ground loop, which may cause distorted images during
projection.
Also note that when using two separate single-axis scanner amplifiers, you run only the POSITION signal
to the PASS position input. DO NOT connect any additional ground wire from each scanner amplifier to
the PASS board. Doing so would introduce a ground loop, which may cause distorted images.
If you are using a one dual-axis scanner amplifier, the recommended connections are shown below:
Since there is only one scanner amplifier in this case, the scanner amplifier is connected directly to the
power supply. If you have two separate power supplies (one for +24V and one for –24V), these can be
connected at the scanner amplifier itself. The PASS board is also connected at the scanner amplifier
itself.
Note that in this case, it is permitted to connect a separate “position signal ground” from the scanner
amplifier to the PASS board if you wish.
PASS Switches
PASS includes a number of switches that must be configured to customize operation to a particular
projector or projection scenario. Below you will see the PASS board and location of the switches. The
operation of each switch is described below.