Appendix B: Mechanical Attachment
(“MA") Strut
Part Number: 5000423 & 2000930
Step 1. Assemble
template for components as
shown, loosely assemble the U-bracket EZ and
MA Strut with the necessary hardware as shown.
Tip:
All hardware is included with
5000423
(MA
Hardware Kit)
Tip:
Install
MA’s
after grid assembly is
completed (prior to installing modules and
deflectors).
Torque Setting*
Fastening Operation
21 ft-lb (29 Nm)
U-
bracket EZ connections (3/8” bolts)
6 ft-lb (8.1 Nm)
Mechanical Attachment Strut to Base connection
Drill with In-Line Torque Limiter or torque wrench
Various sockets (see table)
ALERT: NO IMPACT DRIVERS
* +/-4% allowable during installation
Socket sizes
Fastening Operation
10 mm Magnetic
Used with 6 mm bolts
9/16”
Used with 3/8” bolts
Tools Required:
Torque Clip
3/8” Nut
Mechanical Attachment Strut
2000930
Roof Attachment
Refer to Roof Attachment
Manufacturer’s Instruction
Manual
U-bracket EZ
2000922
3/8” Bolt
3/8” Washer
Torque Clip