PD42-1270 TMCL
™
Firmware Manual • Firmware Version V1.00 | Document Revision V1.0 • 2017-Mar-02
55 / 91
Instruction
Description
Type
Value
135 – get application status
Return information
about the current
status, depending on
the type field.
0 - return mode,
wait flag, memory
pointer
1 - return mode,
wait flag, program
counter
2 - return
accumulator
3 - return X
register
0 (don’t care)
136 – get firmware version
Return firmware
version in string
format (special reply)
or binary format).
0 - string format
1 - binary format
0 (don’t care)
137 – restore factory settings
Reset all settings in
the EEPROM to their
factory defaults.
This command does
not send a reply.
0 (don’t care)
set to 1234
Table 10: TMCL Control Commands
Especially the commands 128, 129, 131 and 136 are interesting for use in custom host applications. The
other control commands are to be used mainly by the TMCL-IDE.
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at
www.trinamic.com
Read entire documentation.