PD42-1270 TMCL
™
Firmware Manual • Firmware Version V1.00 | Document Revision V1.0 • 2017-Mar-02
53 / 91
Reply in Direct Mode
Field
Value
Target address
01
h
Host address
02
h
Status
64
h
(100)
Command
8A
h
(138)
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
Motor bit mask
Checksum
depends also on motor bit mask
Additional Reply after Motor has reached Target Position
Field
Value
Target address
01
h
Host address
02
h
Status
80
h
(128)
Command
8A
h
(138)
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
Motor bit mask
Checksum
depends also on motor bit mask