12.2.1.1 Reset
Instructs the program to start editing a NEW (as yet un-named) serial number file. It will throw
away the information for any serial number currently being edited unless that information has been
saved (Save Button). The new serial number is initialized with one (1) byte of binary.
12.2.1.2 Save
Pops up a Save dialog with the current serial number being edited into the file name and path as
shown in the Serial Number File window. If a file name has not been provided, a dialog will pop up
to allow the user select a file name. Save will save any setup information in the file Serialize.ini.
This file will initialize the setup information the next time the program is started.
12.2.2
Serial Number File
Displays the path and filename of the open Serial File, if saved.
12.2.3
Serial File Unique ID
Displays the unique ID associated with the Serial File. A unique ID is generated anytime a Serial
File is created or modified. Multiple programming images are able to share the same serial
numbers by referencing the same ID number (see
Section 13.6 - Shared Serial Numbers
user can click the “Regenerate” button to assign a new unique ID to the current Serial File.
12.2.4
Serial File Name To Display
The name that will appear in the JSON viewer, Cyclone menu, and in the Name field of the
Cyclone Control GUI. A descriptive name can help to easily differentiate Serial Files.
12.2.5
Serial File Notes
Allows the user to save notes regarding the Serial File. These will appear in the JSON viewer
when viewing the properties of the Serial File, see
Section 13.3 - Serial File Properties
.
12.2.6
Number of Bytes in Serial Number
The up and down arrows allow the user to add or delete bytes for the serial number, the maximum
in hexadecimal = 0x10 (16 base ten), the minimum = 1.
•
Up Arrow Click - Adds new bytes to the Serial Number. Each byte added appears as a
new column in the serial number representation. Added bytes are input as Binary Bytes,
i.e. the upper bound is FF and the lower bound is 00.
•
Down Arrow Click - Deletes bytes from the right end of the Serial Number. Any previously
entered byte properties are lost.
12.2.7
Starting HEX Address
Assigns the starting address (in hexadecimal) of the device memory where the serial number will
be programmed.
12.2.8
Count Sequence
This window lets you test the serial number by counting up or down through the sequencing of the
serial number. The serial number will roll over the upper bounds of the highest serial number back
to the lower bounds of the serial number, and vice versa.
• Up Arrow Click - Counts the serial number up.
• Down Arrow Click - Counts the serial number down.
12.2.9
Serial Number Bytes as Hex
There is one display column for each byte in the serial number shown as printable ASCII
characters. Non-printable ASCII characters are indicated by a blank gray box.
• Up Arrow Click - Counts the serial number up.
Содержание Cyclone FX Series
Страница 1: ...Cyclone LC Programmers User Manual...
Страница 8: ...17 6 Debug Ports CYCLONE LC UNIV 149 17 7 International Shipping 149 17 8 Compliances Standards 149...
Страница 41: ...User Manual For Cyclone LC Programmers 41 Figure 5 2 Main Menu Structure...
Страница 134: ...User Manual For Cyclone LC Programmers 134 4 Click the Add New License button Figure 13 2 Add New License Button...