11
Action at an alarm occurrence
The alarm action will be performed when the following alarms occur.
Alarm type
Terminal alarm:
When connecting an alarm device such as a sensor to the EXT I/O connector 1-3 on the rear of
the camera, the alarm action (camera action at an alarm occurrence) will be performed when the connected
alarm device is activated. Alarm action to be performed differs depending on the settings configured in the
"Camera motion on alarm" section of the [Alarm] tab. (
☞
page 52)
VMD alarm:
When motion is detected in the set VMD area, the alarm action will be performed.
* VMD stands for "Video Motion Detection".
Command alarm:
When a Panasonic alarm protocol (
☞
page 52) is received from the connected device via a
network, the alarm action will be performed.
Action at an alarm occurrence
Display the [Alarm occurrence indication] button on the "Live" page. (
☞
page 7)
The alarm occurrence indication button will be displayed on the "Live" page at an alarm occurrence.
Important:
When "Polling (30 sec)" is selected for "Alarm status update mode" (
☞
page 25), the alarm occurrence indication
button will be refreshed in 30-second intervals. For this reason, it may take a maximum of 30 seconds until the
alarm occurrence indication button is displayed on the "Live" page at an alarm occurrence.
Notify of alarm occurrences to the device connected to the alarm connector
It is possible to output signals from the alarm connector on the rear of the camera and sound the buzzer when an
alarm occurs. The settings for the alarm output can be configured in the "Alarm output terminal" section of the
[Alarm] tab of the "Alarm setup" page. (
☞
page 52)
Transmit an image onto a server automatically
An alarm image can be transmitted at an alarm occurrence to the server designated in advance. The settings
required to transmit an alarm image to a server can be configured in the "Alarm image setup" section of the [Alarm]
tab of the "Alarm setup" page (
☞
page 55) and the [FTP] tab of the "Server setup" page (
☞
page 66).
Important:
Select "FTP error" for "Save trigger" on the [SD memory card] tab when using the SD memory card. When
"Alarm input" or "Manual" is selected for "Save trigger", an alarm image will not be transmitted at an alarm occur-
rence to the FTP server.
Notify of alarm occurrences by e-mail
Alarm mail (alarm occurrence notification) can be sent at an alarm occurrence to the e-mail addresses registered in
advance. Up to 4 addresses can be registered as recipients of the alarm mail. An alarm image (still picture) can be
sent with the alarm mail as an attached file. The settings for alarm mail can be configured in the "E-mail notification
setup" section of the [Notification] tab of the "Alarm setup" page (
☞
page 61) and the [Mail] tab of the "Server setup"
page (
☞
page 65).
Notify of alarm occurrences to the designated IP addresses (Panasonic alarm protocol)
This function is available only when a Panasonic device, such as the network disk recorder, is connected to the sys-
tem. When "ON" is selected for "Panasonic alarm protocol", the connected Panasonic device will be notified that the
camera is in the alarm state. The settings for Panasonic alarm protocol can be configured in the "Panasonic alarm
protocol" section of the [Notification] tab of the "Alarm setup" page. (
☞
page 62)