Check the DIP switch settings before connecting this controller. They need to be changed only if you want to change the sys-
tem settings.
The following setting procedure should be made by qualified service personnel or system installers.
■
DIP Switch Setting
Caution:
Unplug the AC cord before changing any DIP switch setting.
●
Removing the Bottom Cover for SW1
1. Take off the bottom cover by removing the two screws.
CONNECTIONS
●
SW1
SW1 lets you choose 0/5V or open collector (O.C.) for
the alarm recover output signal.
0/5V: +5 V DC approx. 500 m sec.
Open Collector (O.C.): 16 V DC 100 mA max.
The initial factory setting is 0/5V.
Remove two screws.
Bottom Cover
Panasonic
SW1
SW1
O.C
0/5V
NOR:
White with Black border
REV:
Black with White border
The initial factory setting is NOR.
●
SW4
Confirm that SW4 on the board is set as shown below.
This switch is used only for factory tests. Do not change
this switch setting.
●
SW100
SW100 lets you choose the mode for displaying charac-
ters on the monitor.
Bit
ON
OFF
1
2
3
4
SW4
SW100
NOR
REV
●
Removing the Bottom Panel for
SW100
1. Take off the side panels by removing the four screws.
2. Take off the bottom panel by removing the 8 screws.
SW100
Remove four screws.
Remove four screws.
q
w