71
***{ option 0 - Display Alarm Text only
}
***{ option 1 - Display both Alarm Text (20 chars)
}
***{ and Action Text (18 chars)
}
AlarmTextDisplay=1
SYSTEM section
Note:
• This section should not be changed.
Use the admin console to select the correct CPU size.
[SYSTEM]
***{ This section is optional. It is not required unless
}
***{ System defaults are not acceptable. Delete the
}
***{ single asterisks below to make this section active.
}
***{ Format: Keyboards=<num of controllers on this unit> }
***{ Cameras=<num of cameras on this unit>
}
***{ Monitors=<num of monitors on this unit>
}
*Keyboards=64
*Cameras=2048
*Monitors=1024
ROUTING section
Note:
• This section should not be changed.
This section allows the setting of certain network parameters. If changes are necessary, consult your
network administrator.
[ROUTING]
***{ This section is optional to the system. It is only
}
***{ required for external gateway. Delete the single
}
***{ asterisks to make this section active.
}
***{ Only one default gateway is allowed!
}
***{ Format: default=<gateway IPA>
}
The factory default settings below are up is commented out by "*".
* default=192.168.200.1
***{ Network entries must be grouped together although any number of entries is allowed. }
***{ Format: network=<destination>,<gateway>,<netmask>
}
*network=64.0.0.0,192.168.200.44,255,0,0,0
*network=88.0.0.0,192.168.200.88,255,0,0,0
*network=33.5.0.0,192.168.200.66,255,0,0,0
*network=64.0.0.0,192.168.200.55,255,0,0,0
***{ Host entries must be grouped together although any number of entries is allowed.
}
***{ Format: host=<destination>,<gateway>
}
*host=33.44.55.66,192.168.200.66
*host=11.22.33.44,192.168.200.44