18
●
Connection for emergency recording
When the external switch is turned ON, emergency recording will be started.
Recording time and recording rate for emergency recording differ according to the settings of "Emergency REC" on the setup
menu. (Refer to the setup instructions (PDF) for further information about the setup menu.)
●
Connection for external recording changeover
When the external switch is turned ON, the program changeover is affected for recording.
The program can be set by selecting "EXT" for "Time Table" of "Schedule" on the setup menu. (Refer to the setup instructions
(PDF) for further information about the setup menu.)
●
Connection for the Auto Adjust Time function
• When "Auto Adjust Time" of "Time & Date" of "System" on the setup menu is set to "MASTER"
"Time Adjust Output" becomes available and the clock of this unit can be applied to other units.
The time adjust output signal will be supplied from pin no.20 to other unit at the time set for "Time & Date" ("System" – "Time &
Date" – "Time & Date").
Terminal block of other unit
(Time adjust output)
(Earth)
ALARM/CONTROL
(Earth)
Sensor input
Alarm input
Alarm reset input
Series recording input
Time adjust input
(Earth)
Alarm output
Alarm reset output
Alarm recording
During recording
Disk
Buzzer output
System error output
Thermal error output
Time adjust output
Series recording output
!3
@0
Front LED
monitor
output
ALARM/CONTROL
(Earth)
(Emergency recording input)
External switch
!3
!2
External switch
ALARM/CONTROL
(Earth)
!3
@4
(External recording mode input)