19
• When "Auto Adjust Time" of "Time & Date" of "System" on the setup menu is set to "SLAVE"
"Time Adjust Input" becomes available. When a signal output from other equipment is supplied to the time adjust I/O terminals
between 00 minutes 00 seconds and 14 minutes 59 seconds every hour or between 45 minutes 00 seconds and 59 minutes 59
seconds every hour, the clock will be set to "00 minutes 00 seconds" of the closest hour.
Example:
When "15:00" is set for "Time"
Signal is supplied at 14:50:00 (hour:minute:second)
→
Set at 15:00:00
Signal is supplied at 15:14:45
→
Set at 15:00:00
Signal is supplied at 15:20:00
→
Time will not be adjusted.
Important:
When "SLAVE" is selected, the auto time adjustment function works differently depending on the recording status as fol-
lows:
*1: When event recording is performed on any camera channel
ALARM/CONTROL
Terminal block of other unit
(Earth)
Sensor input
Alarm input
Alarm reset input
Series recording input
Time adjust input
(Earth)
Alarm output
Alarm reset output
Alarm recording
During recording
Disk
Buzzer output
System error output
Thermal error output
Time adjust output
Series recording output
Front LED
monitor
output
(Time adjust input)
(Earth)
!3
@0
When no recording is being performed
When manual recording is being performed
When schedule recording is being performed
When event recording is being performed *
1
When emergency recording is being performed
The clock will not be adjusted.
The clock will be adjusted.