1-12. Optional Distribution Joint Kits
See the installation instructions packaged with the distribution joint kit for the installation procedure.
Table 1-12
Model name
Cooling capacity after distribution
Remarks
1. CZ-P680PJ1U
232,000 BTU/h (68.0 kW) or less
For outdoor unit
2. CZ-P1350PJ1U
more than 232,000 BTU/h (68.0 kW)
For outdoor unit
3. CZ-P160BK1U
76,400 BTU/h (22.4 kW) or less*
For indoor unit
4. CZ-P680BK1U
232,000 BTU/h (68.0 kW) or less*
For indoor unit
5. CZ-P1350BK1U
more than 232,000 BTU/h (68.0 kW)*
For indoor unit
n
Tubing size (with thermal insulation)
1. CZ-P680PJ1U
For outdoor unit (Capacity after distribution joint is 232,000 BTU/h (68.0 kW) or less.)
F
E
D
C
HI
H
I
C
C
G
G
G
6-59/64
(175)
5-5/16
(135)
4-21/64
(110)
(97)
3-13/16
4-31/64
(114)
2-53/6
4
(72)
Example:
Gas tubing
Liquid tubing
Distribution
Joint
Distribution
Joint
Reducing
Joints
Reducing
Joints
Unit: in. (mm)
Insulation
Insulation
Table 1-13 Size of connection point on each part (Shown are inside diameters of tubing)
Size
Part A
Part B
Part C
Part D
Part E
Part F
Part G
Part H
Part I
in. (mm)
ø1-3/8"
(ø34.92)
ø1-1/4"
(ø31.75)
ø1-1/8"
(ø28.58)
ø1"
(ø25.4)
ø7/8"
(ø22.22)
ø3/4"
(ø19.05)
ø5/8"
(ø15.88)
ø1/2"
(ø12.7)
ø3/8"
(ø9.52)
2. CZ-P1350PJ1U
For outdoor unit (Capacity after distribution joint is greater than 232,000 BTU/h (68.0 kW).)
(175)
(135)
(110)
(97)
4-31/64
(114)
2-53/6
4
(72)
B
F
H I
H
I
G
G
G
B
B
A
A
6-57/64
5-5/16
4-21/64
3-13/16
C
C
C
D
D
D
E
F
A
Example:
Gas tubing
Liquid tubing
Distribution
Joint
Distribution
Joint
Insulation
Insulation
: Outside dimension
Reducing
Joints
Reducing
Joints
Unit: in. (mm)
*
With regard to the diameter of the tube without description in Table 1-14, use a reducer (field supply) to adjust the tube diameter.
Table 1-14 Size of connection point on each part (Shown are inside diameters of tubing)
Size
Part A
Part B
Part C
Part D
Part E
Part F
Part G
Part H
Part I
in. (mm)
ø1-3/8"
(ø34.92)
ø1-1/4"
(ø31.75)
ø1-1/8"
(ø28.58)
ø1"
(ø25.4)
ø7/8"
(ø22.22)
ø3/4"
(ø19.05)
ø5/8"
(ø15.88)
ø1/2"
(ø12.7)
ø3/8"
(ø9.52)
* In case the total capacity of indoor
units connected after distribution
exceeds the total capacity of the
outdoor units, select the distribution
tube size for the total capacity of the
outdoor units.
00_302411_EN.indd 13
2018/7/4 13:27:18
Содержание U-120ME2U9
Страница 61: ...61 NOTE 00_302411_EN indd 61 2018 7 4 13 28 03 ...
Страница 62: ...62 NOTE 00_302411_EN indd 62 2018 7 4 13 28 03 ...
Страница 63: ...63 NOTE 00_302411_EN indd 63 2018 7 4 13 28 03 ...
Страница 64: ...ACXF60 18511 DC0314 30718 Printed in China 85464369760022 00_302411_EN indd 64 2018 7 4 13 28 04 ...