98
English
Command
Control
AVMT
Shutter control
10: Picture On
(picture mute deactivated)
11: Picture Off
(picture on mute)
20: Audio On
(audio mute deactivated)
21: Audio Off
(audio on mute)
30: Shutter mode Off
(picture and audio mute
deactivated)
31: Shutter mode On
(picture and audio on mute)
AVMT?
Shutter control query
11: Picture Off (picture on mute)
21: Audio Off (audio on mute)
30: Shutter mode Off
(picture and audio mute
deactivated)
31: Shutter mode On
(picture and audio on mute)
ERST?
Error status query
First byte: 0
Second byte: 0
Third byte: 0
Fourth byte: 0
Fifth byte: 0
Sixth byte: Other error. 0 or 2.
●
Meaning of 0, 2.
0: Error is not detected,
2: Error
LAMP?
Lamp status query
Not supported
INST?
Input switch list query
11: PC IN input
31: HDMI 1 input (HDMI1)
32: HDMI 2 input (HDMI2)
33: DisplayPort IN input (DisplayPort)
34: DIGITAL LINK input
(DIGITAL LINK)
35: DVI-D IN input (DVI-D)
36: SLOT input (SLOT)
41: USB input (USB)
42: MEMORY VIEWER input
(MEMORY VIEWER)
51: Screen Transfer input
*
1
(Screen Transfer)
NAME?
Display name query
The name selected in [Display name]
is returned.
INF1?
Manufacturer name query
Returns “Panasonic”.
Command
Control
INF2?
Model name query
Returns “98SQ1W”.
(Example: 98-inch SQ1W model)
INFO?
Other information query
Returns version number.
CLSS?
Class information query
Returns “1”.
*
1: The Screen Transfer input is available for 65/55/49-
inch models.
It is not available for 98/86-inch models.
PJLink security authentication
The password used for PJLink is the same as the
password set for the WEB control. (see page 101)
When using PJLink without security authorization, set
use without the password for administrator privileges
and the password for user privileges of Web browser
control.
●
Concerning the specification of PJLink, see the web
site of Japan Business Machine and Information
System Industries Association (JBMIA) below:
http://pjlink.jbmia.or.jp/english/index.html
Multi Monitoring & Control Software
This unit supports the early warning software “Multi
Monitoring & Control Software” which monitors and
controls devices (projectors or displays) connected to
an intranet, and detects signs of abnormality of such
devices that may arise in future.
As for the early warning function, the maximum number
of devices that can be registered to monitor differs
according to the type of license.
Up to 2 048 devices can be registered for free for
a maximum of 90 days after the installation to the
computer has completed.
●
For more details, visit the following web site.
https://panasonic.net/cns/prodisplays/
●
About early warning function, visit the following web
site.
https://panasonic.net/cns/prodisplays/pass/
Video Wall Manager
This unit supports the “Video Wall Manager” software
which adjusts multiple displays simultaneously or
separately on one computer without rearranging cables.
●
For more details, visit the following web site.
https://panasonic.net/cns/prodisplays/