57
English
Power on screen delay
You can set the power-on delay time of the displays to
reduce the power load, when you press <Main Power
On / Off button> to turn on the multiple displays that are
set together.
Set each display’s setting individually.
[Off]:
The display will be turned on at the same time as
<Main Power On / Off button> is pressed.
[Auto]:
Sets the delay time automatically according to the
number set for [Display ID].
The delay time is determined by multiplying
[Display ID] × 0.3 seconds.
Example:
When [Display ID
] is 3 → 0.9 seconds
1 ‒ 30:
Set the power-on delay time (second).
After pressing <Main Power On / Off button>,
the display will be powered on with time delay
depending on this setting.
Note
●
While this function is working, the power indicator is
blinking green.
●
This function also works when the power recovers
from failure or after plugging off and in again the
power cord.
Clock display
Sets to display / hide the clock.
[Off]:
Hides the clock.
[On]:
Displays the clock.
Note
●
The clock is displayed at the lower left of the screen
when <RECALL> button is pressed.
●
When current date and time is not set, the clock is
not displayed even when [Clock display] is [On]. (see
page 48)
Power on message(No activity power
off)
Sets to show/hide [No activity power off] precautions at
the time the unit is turned on.
[On]:
The warning precautions are shown at the time of
power ON.
[Off]:
The warning precautions are not shown at the time
of power ON.
Note
●
This setting is enabled only when [No activity power
off] is [Enable] (see page 46).
Power on message(Power
management)
Whether to show/hide an information message that tells
the power has been turned off by “Power management”
function when the power is set to [On].
[On]:
The information is shown at the time of power [On].
[Off]:
The information is not shown at the time of power
[On].
Note
●
This setting is enabled only when “Power
management” function is [On] (see page 44).
POWER button lock
Sets the lock setting for the display <Main Power On /
Off button>.
[On]:
<Main Power On / Off button> operation is
disabled.
[Off]:
<Main Power On / Off button> operation is
enabled.
Initialization
When both main unit buttons and remote control buttons
are disabled due to the [Button lock], [Controller user
level] and [Controller ID function] settings, set all the
values [Off] so that all the buttons are enabled again.
Press <- (Unit)> together with <RETURN>
and hold for more than 5 seconds.
[Shipping] is displayed and the lock is released when
it disappears.
Shipping
YES
NO
●
Settings for [Button lock], [Controller user level]
and [Controller ID function] will be back to [Off].