6.1 Specifications, Controller ST4-C11
89
Item
Description
Storage: -25 to +70°C
Ambient humidity
30 to 85% RH, Storage: 30 to 95% RH
Withstand voltage
1,000V AC for one minute (between all supply terminals connected together and
enclosure)
Insulation resistance
20M
Ω
or more with 500V DC (between all supply terminals connected together and
enclosure)
Vibration resistance
10 to 55Hz frequency
0.75mm amplitude in X, Y, and Z directions for two hours each
Shock resistance
300m/s2 acceleration in X, Y, and Z directions for three times each
Terminal block
Detachable spring cage terminal
Distributing cable
Terminal block connector: 0.2 to 1.5mm
2
Material
Enclosure: ABS
Weight
Approx. 180g
Applicable standard
(Note 2)
IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe)
IEC 61508-1 to 7 (SIL3), IEC 62061 (SIL3)
NOTE
1. If the total current of both the control output (OSSD 1/2) and auxiliary output
exceeds 400mA, the wiring resistance between the controller and the power
supply should be 1
Ω
or less. In addition, if the total current is 400mA or less,
the wiring resistance between the controller and the power supply should be
2
Ω
or less.
2. Complies with these standards only when the controller is used in
combination with the single-beam sensor ST4-
□
.