![Panasonic ST4 Series Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/panasonic/st4-series/st4-series_instruction-manual_278037045.webp)
Panasonic ST4 Instruction Manual
2.5 Wiring
37
(where CE certification is required). The power supply unit must conform to CLASS 2
(where UL/cUL certification is required).
•
If the power supply conforms to the Low-Voltage Directive and has an output of 100VA
or less, it is suitable.
•
The frame ground (F.G.) terminal must be connected to ground when using a
commercially available switching regulator.
•
The power supply unit must have an output holding time of 20ms or more.
•
If there is a possibility of surge, take countermeasures such as connecting a surge
absorber to the origin of the surge.
2.5.2 I/O
Circuit
Diagrams
The following diagrams show the circuits of the controller and the wiring for different functions
and parts of the system.
2.5.2.1 Circuit of Controller ST4-C11
Controller ST4-C11
PNP output
T1 T2
OSSD1 OSSD2
0V
AUX
IU+ IU- IL+ IL-
0V
A2
A1
24V
X1 X2 X3
KA
KA
KB
KB
PNP
NPN
Ui
2
Reset
1
3
4
5
1
= Main circuit
2
= Emitter side
3
= Receiver side
4
= Output polarity switch
5
= Emission halt input
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG