![Panasonic ST4 Series Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/panasonic/st4-series/st4-series_instruction-manual_278037041.webp)
Panasonic ST4 Instruction Manual
2.4 Mounting and Removing
33
!
DANGER!
If you hook up the connectors incorrectly or mix connecting the
emitters and receivers, the device will not operate properly. This
may result in serious injury or death.
The cable length between all emitters and the controller, as well
as between all receivers and the controller, must not exceed
50m, respectively. If this length is exceeded it leads to improper
operation of the device, resulting in serious injury or death.
After installing the ST4-A
□
, check that the ST4-A
□
detects a part
of human body before it reaches to the dangerous part of the
machine, by watching the beam interruption indicator (red). Also
check that ST4-A
□
is installed in a proper position.
The emitter of the ST4-A
□
(connector color: gray) has to be connected with the emitter
connector of the controller (connector color: gray). The receiver of the ST4-A
□
(connector color:
black) has to be connected with the receiver connector of the controller (connector color: black).
NOTE
•
Addresses of the ST4-A
□
are allocated in the order of the numbers that are
marked on the main body of ST4-CCJ05-WY (optional).
•
Connect the ST4-A
□
s to the connector numbers 2 and 3 of the branch cable
ST4-CCJ05-WY (optional). If the ST4-A
□
s are not connected to the
connectors 2 and 3, the device will not operate properly. For an unconnected
condition, the fault indicator (yellow) of ST4-C11 blinks once. For
ST4-C12EX, " " is indicated on the fault display (red).
1
2
3
To connect the sensor in series, you need at least two sets of receiver and emitter of the
ST4-A
□
, two extension cables ST4-CCJ
□
s and two branch cables ST4-CCJ05-WY.
1.
2.
3.
Procedure