Troubleshooting
Panasonic ST4 Instruction Manual
80
5.1 Troubleshooting of Controller ST4-C11
First of all, check the wiring, the power supply voltage and the power supply capacity.
The number of blinks of the fault indicator (yellow) on ST4-C11 varies depending on the
condition of error as shown in the following table.
Symptom
Cause
Remedy
Power is not being supplied.
Check that the power supply capacity is
sufficient.
Connect the power supply correctly.
All indicators are
OFF.
Supply voltage is out of the specified
range.
Set the supply voltage to 24V DC
+10
-15
%.
Emission halt input
indicator (orange)
lights up.
The controller is in the emission halt
condition.
Check that the emission halt input terminals
(between T1 and T2) short-circuit.
Reset input
terminal is not
wired.
Wire the reset input terminals correctly (manual
reset: between X1 and X2, or auto reset:
between X1 and X3).
To ensure the safety of the system, use the NC
contact of a forcibly guided relay.
Relay is welded.
Replace the relay.
Relay response
time is slow.
Replace the relay with proper response time.
Interlock indicator
(yellow) lights up.
Reset condition is
not cancelled.
Reset signal at
start-up is not
input. (manually)
Use a momentary switch.
Replace the switch.
Large noise
Check the noise condition around this device.
Fault indicator
lights up
Microcomputer
error
Internal error
Replace the ST4-C11.
The emitters and receivers are of
different types.
Use the same type of emitter and receiver. Do
not mix them.
Series connection condition is out of the
specified range.
Set the series connection condition within the
specified range (see "Connecting Multiple
Sensors Heads" on page 23).
The serial signal short-circuits.
Check that the cable of ST4-A
□
, ST4-CCJ
□
(optional) or ST4-CCJ05-WY (optional) is not
disconnected and the connectors are not loose.
Fault indicator
blinks once
•
Error
between
emitter and
receiver of
ST4-A
□
The connected ST4-A
□
is faulty.
Check the indicator of the connected ST4-A
□
(see "Connecting Multiple Sensors Heads" on
page 23).
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG