4
-
Areas exposed to intense interference light such as direct sunlight
-
Areas with high humidity where condensation is likely to occur
-
Areas exposed to corrosive or explosive gases
-
Areas exposed to vibration or shock at levels higher than those specified
-
Areas exposed to contact with water
-
Areas exposed to excessive steam or dust
-
Areas where the beam-receiving part of this device is directly exposed to
light from a high-frequency fluorescent lamp (inverter type) or
rapid-starter fluorescent lamp.
Installation
•
Always keep the correctly calculated safety distance between the safety
beam sensor and the dangerous parts of the machine.
•
Install an extra protective structure around the machine so that the operator
must pass through the sensing area of the safety beam sensor to reach the
dangerous parts of the machine.
•
Install the beam sensor in a manner that some part of the operator's body
always remains in the sensing area until the operator has finished working
with the dangerous parts of the machine.
•
Do not install the beam sensor at a location where it can be affected by wall
reflection.
•
When installing multiple sets of the safety beam sensor, connect the sets
and, if necessary, install some barriers so that mutual interference does not
occur.
•
Do not use any reflection type or recursive reflection type arrangement.
Equipment in which this device is installed
•
When the safety beam sensor is used in the PSDI mode, an appropriate
control circuit must be configured between this device and the machinery.
For details, be sure to refer to the standards or regulations applicable in each
region or country.
•
In Japan, do not use the safety beam sensor as safety equipment for a press
machine.
•
Do not install the safety beam sensor with a machine whose operation
cannot be stopped immediately in the middle of an operation cycle by an
emergency stop.
•
This sensor provides safety 2 seconds after the power has been switched
ON. Make sure that the control system takes the time delay into
consideration.
Wiring
•
Switch off the power before wiring the safety beam sensor.
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
www.sentronic.com