14

12)  HL00 + 0080 to HL00 + 00BF, HL00 + 0180 to HL00 + 01BF: Address information bank

register (read out only)

Relationship between “Computer I/O address” and “S-LINK V address”

Computer I/O address
(hexadecimal)

S-LINK V

 address

Port 1

Port 2

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

HL00 + 0080

HL00 + 0180

7

6

5

4

3

2

1

0

HL00 + 0081

HL00 + 0181

15

14

13

12

11

10

9

8

HL00 + 0082

HL00 + 0182

23

22

21

20

19

18

17

16

HL00 + 0083

HL00 + 0183

31

30

29

28

27

26

25

24

HL00 + 0084

HL00 + 0184

39

38

37

36

35

34

33

32

HL00 + 0085

HL00 + 0185

47

46

45

44

43

42

41

40

HL00 + 0086

HL00 + 0186

55

54

53

52

51

50

49

48

HL00 + 0087

HL00 + 0187

63

62

61

60

59

58

57

56

HL00 + 0088

HL00 + 0188

71

70

69

68

67

66

65

64

HL00 + 0089

HL00 + 0189

79

78

77

76

75

74

73

72

HL00 + 008A

HL00 + 018A

87

86

85

84

83

82

81

80

HL00 + 008B

HL00 + 018B

95

94

93

92

91

90

89

88

HL00 + 008C

HL00 + 018C

103

102

101

100

99

98

97

96

HL00 + 008D

HL00 + 018D

111

110

109

108

107

106

105

104

HL00 + 008E

HL00 + 018E

119

118

117

116

115

114

113

112

HL00 + 008F

HL00 + 018F

127

126

125

124

123

122

121

120

HL00 + 0090

HL00 + 0190

135

134

133

132

131

130

129

128

HL00 + 0091

HL00 + 0191

143

142

141

140

139

138

137

136

HL00 + 0092

HL00 + 0192

151

150

149

148

147

146

145

144

HL00 + 0093

HL00 + 0193

159

158

157

156

155

154

153

152

HL00 + 0094

HL00 + 0194

167

166

165

164

163

162

161

160

HL00 + 0095

HL00 + 0195

175

174

173

172

171

170

169

168

HL00 + 0096

HL00 + 0196

183

182

181

180

179

178

177

176

HL00 + 0097

HL00 + 0197

191

190

189

188

187

186

185

184

HL00 + 0098

HL00 + 0198

199

198

197

196

195

194

193

192

HL00 + 0099

HL00 + 0199

207

206

205

204

203

202

201

200

HL00 + 009A

HL00 + 019A

215

214

213

212

211

210

209

208

HL00 + 009B

HL00 + 019B

223

222

221

220

219

218

217

216

HL00 + 009C

HL00 + 019C

231

230

229

228

227

226

225

224

HL00 + 009D

HL00 + 019D

239

238

237

236

235

234

233

232

HL00 + 009E

HL00 + 019E

247

246

245

244

243

242

241

240

HL00 + 009F

HL00 + 019F

255

254

253

252

251

250

249

248

HL00 + 00A0

HL00 + 01A0

263

262

261

260

259

258

257

256

HL00 + 00A1

HL00 + 01A1

271

270

269

268

267

266

265

264

HL00 + 00A2

HL00 + 01A2

279

278

277

276

275

274

273

272

HL00 + 00A3

HL00 + 01A3

287

286

285

284

283

282

281

280

HL00 + 00A4

HL00 + 01A4

295

294

293

292

291

290

289

288

HL00 + 00A5

HL00 + 01A5

303

302

301

300

299

298

297

296

HL00 + 00A6

HL00 + 01A6

311

310

309

308

307

306

305

304

HL00 + 00A7

HL00 + 01A7

319

318

317

316

315

314

313

312

HL00 + 00A8

HL00 + 01A8

327

326

325

324

323

322

321

320

HL00 + 00A9

HL00 + 01A9

335

334

333

332

331

330

329

328

HL00 + 00AA

HL00 + 01AA

343

342

341

340

339

338

337

336

HL00 + 00AB

HL00 + 01AB

351

350

349

348

347

346

345

344

HL00 + 00AC

HL00 + 01AC

359

358

357

356

355

354

353

352

HL00 + 00AD

HL00 + 01AD

367

366

365

364

363

362

361

360

HL00 + 00AE

HL00 + 01AE

375

374

373

372

371

370

369

368

HL00 + 00AF

HL00 + 01AF

383

382

381

380

379

378

377

376

HL00 + 00B0

HL00 + 01B0

391

390

389

388

387

386

385

384

HL00 + 00B1

HL00 + 01B1

399

398

397

396

395

394

393

392

HL00 + 00B2

HL00 + 01B2

407

406

405

404

403

402

401

400

HL00 + 00B3

HL00 + 01B3

415

414

413

412

411

410

409

408

HL00 + 00B4

HL00 + 01B4

423

422

421

420

419

418

417

416

HL00 + 00B5

HL00 + 01B5

431

430

429

428

427

426

425

424

HL00 + 00B6

HL00 + 01B6

439

438

437

436

435

434

433

432

HL00 + 00B7

HL00 + 01B7

447

446

445

444

443

442

441

440

HL00 + 00B8

HL00 + 01B8

455

454

453

452

451

450

449

448

Содержание SL-VVMES2

Страница 1: ... Panasonic Industrial Devices SUNX Co Ltd 2013 CMJE SLVVMES2 No 0037 87V INSTRUCTION MANUAL Sensor Wire saving Link System S LINK VME Bus S LINK V Control Board SL VVMES2 ...

Страница 2: ...as short as possible Take care that wrong wiring will damage the product Wiring This product has been developed produced for industrial use only In case noise generating equipment switching regulator inverter motor etc is used in the vicin ity of this product connect the frame ground F G terminal of the equipment to an actual ground This product does not have a dust proof or water proof constructi...

Страница 3: ...wo places 2 Push out the knobs to remove SL VVMES2 and pull it out from the VME bus rack 3 If required mount the backplane jumper that corresponds to the slot inside the VME bus rack Notes 1 For details of mounting and removing refer to the instruction manual of VME bus rack 2 When mounting SL VVMES2 be sure to pull out the backplane jumper that corresponds to the slot inside the VME bus rack If t...

Страница 4: ...connector for port 2 1 S LINK V terminal block connector for port 1 5 System setting button for port 2 7 BUSY indicator for port 2 Orange 8 Error indicator for port 2 Red 16 5 186 1 169 6 Unit mm 1 S LINK V terminal block connector Connect main line and power supply of S LINK V system Port 1 and port 2 is independent re spectively 7 6 5 4 3 2 1 G D 0 24 0 24 FG IN View from wiring side No Terminal...

Страница 5: ...n power is supplied to the computer Changing the mode switch setting during operation is ineffective The setting cannot be changed with the reset command on the S LINK V system side Transmission mode setting switch Transmission mode SW3 1 SW6 1 SW3 2 SW6 2 A mode OFF OFF B mode OFF ON C mode ON OFF A mode ON ON I O control number setting switch I O control number SW3 5 SW6 5 SW3 6 SW6 6 SW3 7 SW6 ...

Страница 6: ...Address ON OFF SW2 1 SW5 1 0 to 31 Input Output SW2 2 SW5 2 32 to 63 SW2 3 SW5 3 64 to 95 SW2 4 SW5 4 96 to 127 SW2 5 SW5 5 128 to 159 SW2 6 SW5 6 160 to 191 SW2 7 SW5 7 192 to 223 SW2 8 SW5 8 224 to 255 SW1 1 SW4 1 256 to 287 SW1 2 SW4 2 288 to 319 SW1 3 SW4 3 320 to 351 SW1 4 SW4 4 352 to 383 SW1 5 SW4 5 384 to 415 SW1 6 SW4 6 416 to 447 SW1 7 SW4 7 448 to 479 SW1 8 SW4 8 480 to 511 Note When se...

Страница 7: ... main line or the input of the input unit is changed it processes at the interruption level that is set with the interruption level setting switch The above figure indicates the interruption level IRQ1 0 1 SW8 1 2 3 4 5 6 7 8 O N Level 1 2 3 4 5 6 7 8 Unused OFF OFF OFF OFF IRQ1 ON OFF OFF IRQ2 OFF ON OFF IRQ3 ON ON OFF IRQ4 OFF OFF ON IRQ5 ON OFF ON IRQ6 OFF ON ON IRQ7 ON ON ON Note Settings othe...

Страница 8: ...gister R 2 bytes 1 word 0152H Bank change over response register R 2 bytes 1 word 0054H Communication stop Reset R W 2 bytes 1 word 0154H Communication stop Reset R W 2 bytes 1 word 0056H Input hold Input change interruption Input change interruption oc currence condition Error interruption R W 2 bytes 1 word 0156H Input hold Input change interruption Input change interruption oc currence conditio...

Страница 9: ... 0119 207 206 205 204 203 202 201 200 HL00 001A HL00 011A 215 214 213 212 211 210 209 208 HL00 001B HL00 011B 223 222 221 220 219 218 217 216 HL00 001C HL00 011C 231 230 229 228 227 226 225 224 HL00 001D HL00 011D 239 238 237 236 235 234 233 232 HL00 001E HL00 011E 247 246 245 244 243 242 241 240 HL00 001F HL00 011F 255 254 253 252 251 250 249 248 HL00 0020 HL00 0120 263 262 261 260 259 258 257 25...

Страница 10: ...73 472 HL00 003C HL00 013C 487 486 485 484 483 482 481 480 HL00 003D HL00 013D 495 494 493 492 491 490 489 488 HL00 003E HL00 013E 503 502 501 500 499 498 497 496 HL00 003F HL00 013F 511 510 509 508 507 506 505 504 2 HL00 0040 to 1 HL00 0140 to 1 Transmission mode I O control points read out only Transmission mode and I O control points are stored HL00 0040 HL00 0140 bit 7 6 5 4 3 2 1 0 I O contro...

Страница 11: ...367 Address 480 to 495 Address 112 to 127 Address 240 to 255 Address 368 to 383 Address 496 to 511 0 Input 1 Output 4 HL00 0046 to 7 HL00 0146 to 7 S LINK V I O unit connected node number read out only It shows the number of nodes to which S LINK V I O units are connected 0 to 256 nodes 5 HL00 004A to B HL00 014A to B Error No Error state read out only bit 0 to 3 Occurred error No is displayed 0H ...

Страница 12: ...00 004C or HL00 014C bit 4 to execute and the clearance is completed when HL00 004E or HL00 014E bit 4 turns to 0 In case 0 is written into HL00 004C or HL00 014C bit 4 it is ignored After the clearance in case HL00 004C or HL00 014C bit 4 does not return to 0 it will be cleared soon after the next interruption occurs bit 5 Busy indication When the Busy indicator lights up such as during system se...

Страница 13: ...12 HL00 0080 to HL00 00BF HL00 0180 to HL00 01BF Address information bank register until 9 over response register has been changed over 3 Even if write into HL00 0051 HL00 0151 HL00 0053 and HL00 0153 it is ignored 10 HL00 0054 to 5 HL00 0154 to 5 Transmission stop Reset In order to stop the transmission of S LINK V system write 0FH into HL00 0054 or HL00 0154 In order to restart it write in the r...

Страница 14: ...d in units of one channel bit 3 Error interruption sets whether an interruption occurs or not when an error occurs When bit 3 is 1 an interruption occurs and when bit 3 is 0 the interruption does not occur In case the error interruption is set to effective the interruption occurs with OR operation applied to all error occurrences For contents of error check by 5 HL00 004A to B HL00 014A to B Error...

Страница 15: ...2 HL00 0099 HL00 0199 207 206 205 204 203 202 201 200 HL00 009A HL00 019A 215 214 213 212 211 210 209 208 HL00 009B HL00 019B 223 222 221 220 219 218 217 216 HL00 009C HL00 019C 231 230 229 228 227 226 225 224 HL00 009D HL00 019D 239 238 237 236 235 234 233 232 HL00 009E HL00 019E 247 246 245 244 243 242 241 240 HL00 009F HL00 019F 255 254 253 252 251 250 249 248 HL00 00A0 HL00 01A0 263 262 261 26...

Страница 16: ...esponse register 02H Error 3 occurred address S LINK V I O unit is indicated When each bit is 1 the S LINK V I O unit connected to the address is disconnected or in er ror In case Bank change over response register 03H Error 4 occurred address S LINK V I O unit is indicated S LINK V I O unit having the allocated address In case Bank change over response register 04H Error 5 occurred address S LINK...

Страница 17: ... SL VVMES2 Internal circuit reads out bank number of the bank change over request register SL VVMES2 Internal circuit switches the data area to the information corresponding to the bank number SL VVMES2 The internal circuit switches to the bank change over response register and then writes in the bank number User s computer It reads out bank number of the bank change over response register User s ...

Страница 18: ... 00D9 HL00 01D9 207 206 205 204 203 202 201 200 HL00 00DA HL00 01DA 215 214 213 212 211 210 209 208 HL00 00DB HL00 01DB 223 222 221 220 219 218 217 216 HL00 00DC HL00 01DC 231 230 229 228 227 226 225 224 HL00 00DD HL00 01DD 239 238 237 236 235 234 233 232 HL00 00DE HL00 01DE 247 246 245 244 243 242 241 240 HL00 00DF HL00 01DF 255 254 253 252 251 250 249 248 HL00 00E0 HL00 01E0 263 262 261 260 259 ...

Страница 19: ...rates interruption Computer I O address hexadecimal S LINK V address Port 1 Port 2 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 HL00 00F9 HL00 01F9 463 462 461 460 459 458 457 456 HL00 00FA HL00 01FA 471 470 469 468 467 466 465 464 HL00 00FB HL00 01FB 479 478 477 476 475 474 473 472 HL00 00FC HL00 01FC 487 486 485 484 483 482 481 480 HL00 00FD HL00 01FD 495 494 493 492 491 490 489 488 HL00 00FE...

Страница 20: ...ability Note 4 1 000V AC for one min between external terminals and ground Insulation resistance Note 4 Z ZZ Vibration resistance Note 4 10 to 150Hz frequency 0 75mm amplitude or acceleration 5G in X Y and Z directions for two hours each Shock resistance Note 4 98m s2 acceleration approx 10G in X Y and Z directions for three times each Grounding method Bracket Floating S LINK V system side Capacit...

Страница 21: ...20 MEMO ...

Страница 22: ...DIRECT INCIDENTAL SPECIAL OR CON SEQUENTIAL DAMAGES OF ANY KIND GENERAL TERMS AND CONDITIONS 4 OR ANY DAMAGES RESULTING FROM LOSS OF USE BUSINESS INTERRUPTION LOSS OF INFORMATION LOSS OR INACCURACY OF DATA LOSS OF PROFITS LOSS OF SAVINGS THE COST OF PROCUREMENT OF SUBSTITUTED GOODS SERVICES OR TECHNOLOGIES OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODU...