9
This is an area to read out input data and write in output data of
S-LINK V
I/O units.
In case of input data, “0: Input OFF” or “1: Input ON” can be read out for each bit.
In case of output data, write in “0: Output OFF” or “1: Output ON” in each bit.
Notes: 1) Output is maintained until overwritten with the next output data.
2) In case output data is written into a unit address which has been set as an input, the written data is
ignored and input data is set after 1 or 2 refresh times.
Computer I/O address
(hexadecimal)
S-LINK V
address
Port 1
Port 2
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
HL00 + 0039
HL00 + 0139
463
462
461
460
459
458
457
456
HL00 + 003A
HL00 + 013A
471
470
469
468
467
466
465
464
HL00 + 003B
HL00 + 013B
479
478
477
476
475
474
473
472
HL00 + 003C
HL00 + 013C
487
486
485
484
483
482
481
480
HL00 + 003D
HL00 + 013D
495
494
493
492
491
490
489
488
HL00 + 003E
HL00 + 013E
503
502
501
500
499
498
497
496
HL00 + 003F
HL00 + 013F
511
510
509
508
507
506
505
504
2) HL00 + 0040 to 1, HL00 + 0140 to 1: Transmission mode / I/O control points (read out only)
Transmission mode and I/O control points are stored.
HL00 + 0040 / HL00 + 0140
bit
7
6
5
4
3
2
1
0
I/O control points
512 480 448 416 384 352 320 288 256 224 192 160 128
96
64
32
Indication
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
Transmission mode
A mode
B mode
C mode
Indication
0
1
0
0
0
1
Unused
(= 0)
bit 0 to 3 : I/O control number information is stored.
bit 6, 7 : Transmission mode information is stored.
Notes: 1) No writing is allowed. In order to change the setting, use the dip switches on the board.
2) Even if write into HL00 + 0041 and HL00 + 0141, it is ignored.