Functional Descriptions
3-1-9 Protective Function
The functional settings are not allowed to change without the input of a password.
When the protective function is set to “effective,” the setting can be changed by inputting the password.
The setting contents monitor function can be used regardless of the protective function “effective / ineffective.”
The password should be a 4-digit number from 0 to 9. (The password of the factory setting is “0000.”)
The protective function is set on the receiver side.
3-1-10 Initialization Function
The settings can be initialized. (factory setting) (Note)
The factory setting of each function is as follows.
Function
Setting
Fixed blanking function
Ineffective
Floating blanking function
Ineffective
Auxiliary output switching function
Mode 0
Emission intensity control function
Normal mode
Muting setting
changing func-
tion
Setting of the muting function on each beam channel
Effective for all beam channels
Muting input conditions
A = B
Setting of the muting lamp diagnosis function (Ver. 2 or later)
Effective
Muting sensor output operation setting
(Ver. 2.1 only)
NONO
Interlock setting changing function
Start / Restart
External devise monitor setting changing function
Effective / 300ms
Override setting changing function (Ver. 2.1 only)
60 sec.
Note: The setting of the protective function and the setting data of the copy function are not initialized.
3-1-11 Setting Contents Monitoring Function
Each setting of the
SF4B
/
SF4B<V2>
series can be monitored. The following can be monitored.
Model No. / the number of beam channels
&*&{&$Y
&=&&{&$Y
Setting of the auxiliary output switching function
Setting of the emission intensity control function
Setting of the muting setting changing function
(Reading out the record of the latest 5 times is possible, however, only for setting beam channel.)
Setting of the interlock setting changing function
Setting of the external device monitor setting changing function
Override setting changing function
3-1-12 Override Setting Changing Function (Ver. 2.1 only)
Maximum continuous effective time set at the override function can be changed.
The maximum continuous effective time can be set in the range of 60 to 600 sec. (in units of 10 sec.).
The factory setting is 60 sec.
When the protecting function is set to “ineffective,” the third person may change the set-
ting. It is recommended that the protecting function should be set to “effective” so as not
to change the setting by the third person.
~ & ; @ % & ;+