32
© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V
Function Setting
*: The functional setting of each beam channel is as follows.
on : The muting function is effective.
oFF : The muting function is ineffective.
CLR initializes the all settings. (factory setting)
_ All beam channels: Effective
_ Input condition: A = b
_ Muting lamp diagnosis function setting: Effective
When changing only the setting of the muting input condition, set it by manual setting.
The input condition can be set at
SF4B
/
SF4B<V2>
series respectively.
When initializing only the beam channel that the muting is effective, set to the auto setting in the
emission halt condition.
Notes: 1) “ALL” is displayed only when set by “Auto.”
2) When only using the
SF4B
/
SF4B<V2>
series, set the muting lamp diagnosis function on all
SF4B
/
SF4B<V2>
series.
However, if the function has been set through CLr / Auto / ManU on each
SF4B
/
SF4B<V2>
series, set the function on
the
SF4B
/
SF4B<V2>
series. When using
SF-C14EX
, this function is set on the
SF-C14EX
. In this case, set the func-
tion in the same way when “ALL” is selected.
3) It is not indicated when using with
SF4B
series. In addition, it is not indicated when using with
SF-C14EX
,
either.