Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
53
*S1
Switch S1
●
Test / Reset input
Manual reset …0 to 2.5V (source current 5mA or less): Emission halt, Open: Emission
Auto reset …0 to 2.5V (source current 5mA or less): Emission, Open: Emission halt
● Interlock setting input, Override input, Muting input A / B, External device monitor input
0 to +2.5V (source current 5mA or less): Valid, Open: Invalid
<Reference>
● K1, K2: External device (forcible guide relay or magnetic conductor)
●
For wiring, refer to 2-5-4 and following sections.