<Output operation of muting sensors>
Operation
when ON
Operation
when OFF
NO (Normally Open) type
ON when light not received (photoelectric sensor, etc.)
ON when object approaches (proximity sensor, etc.)
ON when contact occurs (position switch, etc.)
0V or +V
Open
WARNING
Use only a muting sensor that is capable of the above
<Output operation of muting sensors>
.
If a muting sensor other than the above is used, the muting function may activate at a time not in-
tended by the machine designer and create a risk of death or serious injury.
<Start conditions for muting>
The muting state activates when the following conditions are all satisfied.
●
The device is not in the lockout state.
● The device is in the light receiving state and the control output (OSSD 1 / 2) is ON.
● The time difference when muting inputs A and B change to ON is from 0.03 to under 3 sec.
<Release conditions for muting>
The muting state deactivates when any one of the following conditions is satisfied.
●
The device enters the lockout state.
● Muting input A or B turned OFF for at least 20ms.
●
The muting time exceeded two hours.
<Example of muting sensor installation conditions>
Light curtain
Muting sensor C
Muting sensor D
Muting sensor B
Muting sensor A
Sensing object
S (m/sec)
(1)
(1)
(2)
(3)
Safe zone
Danger zone
Guard
Guard
(1) The distance between muting sensors A and
C, and B and D, must be shorter than the total
length of the sensing object.
(2) The time required for the sensing object to pass
from muting sensor A to muting sensor B must be
0.03 sec to under 3 sec.
Distance between muting sensors A and B (m) <
S (m/sec.) x 3 (sec.)
S: Velocity (m/sec.) of sensing object
(3) The time required for the sensing object to pass
from muting sensor C to muting sensor D must
be under 3 sec.
Distance between muting sensors C and D (m) <
S (m/sec.) x 3 (sec.)
S: Velocity (m/sec.) of sensing object
Содержание SF4D-x-01 Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Страница 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Страница 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Страница 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...