Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
67
<Using NPN output>
Emitter
Receiver
K1
K2
+
24V DC
+20
-30
%
−
Gray cable
Gray cable
(with black line)
(Brown) +V
(Brown) +V
(Pale purple) Interlock setting input
(Gray / Black) Application indicator input 2
(Gray) Application indicator input 1
(Pink) Test / Reset input
(Red / White) Muting auxiliary output
(Red) Auxiliary output 1
(Pale blue) Output polarity setting / Lockout release input
(Yellow) Override input
(Pale blue) Output polarity setting / Lockout release input
(Red) Auxiliary output 2
(Gray) NC
(Blue) 0V
(Blue) 0V
(Orange) Synchroni
(Pale purple) External device monitor input
(Black) Control output 1 (OSSD 1)
(Pink) Muting input A
(White) Control output 2 (OSSD 2)
(Yellow) Muting input B
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
*S2
*S2
*S1
*S2
Interlock function
Invalid (auto reset)
External device monitor function Invalid
Auxiliary output 1
Not possible
*Symbols
Switch S1
●
Test / Reset input
0 to +2.5V (source current 5mA or less): Emission, Open: Emission halt
Switch S2
● Muting input A / B, Override input
0 to +2.5V (source current 5mA or less): Valid, Open: Invalid
K1, K2: Safety relay unit, etc.
Содержание SF4D-x-01 Series
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Страница 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Страница 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Страница 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Страница 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...