Remove the indicator cover from the device to access the DIP switches.
Device
Indicator cover
M2.6 screw (length 7mm)
4
3
2
1
<DIP switches>
ON
OFF
CAUTION
●
After setting the DIP switches, always reattach the indicator cover on the device.
Tighten to a torque of 0.3N·m or less.
● There is packing on the indicator cover. If the packing is not fitted on the cover properly, fit as
shown below before attaching to the device.
Indicators on emitter side
Frequency indicator
(Orange)
Light emission inten-
sity control indicator
(Orange)
Upper application indicator
(Blue / Red / Green / Orange)
Lower application indicator
(Blue / Red / Green / Orange)
Indicators on receiver side