[PICTURE] menu
ENGLISH - 71
Settings
[NOISE REDUCTION]
You can reduce noises when the input image is
degraded and noise is occurring in the image signal.
1) Press
▲▼
to select [NOISE
REDUCTION].
2) Press
◀▶
or the <ENTER> button.
▶
z
The
[NOISE REDUCTION]
individual
adjustment screen is displayed.
3) Press
◀▶
to switch the [NOISE
REDUCTION].
▶
z
The setting will change as follows each time
you press the button.
[1] (Low)
[2] (Medium)
[OFF] (No
correction)
[3] (High)
Attention
z
When this is set for an input signal with less noise,
the image may look different from what it originally
was. In such case, set it to [OFF].
[DYNAMIC IRIS]
Aperture correction and signal compensation are
performed automatically based on the image to result
in an image of optimum contrast.
1) Press
▲▼
to select [DYNAMIC IRIS].
2) Press
◀▶
or the <ENTER> button.
▶
z
The
[DYNAMIC IRIS]
individual adjustment
screen is displayed.
3) Press
◀▶
to switch the [DYNAMIC
IRIS].
▶
z
The setting will change as follows each time
you press the button.
[OFF] (No
correction)
[1] (Small)
[2]
(Medium)
[USER]
[3] (Large)
▶
■
To adjust desired correction
amount
4) Select [USER] in Step 3).
5) Press the <ENTER> button.
▶
z
The
[DYNAMIC IRIS]
screen is displayed.
6) Press
▲▼
to select the item you want
to adjust, and press
◀▶
to adjust the
correction amount.
▶
z
Auto Iris (Automatic adjustment of
aperture)
[OFF] (no automatic
adjustment)
[1] (Small)
[255] (Large)
[254] (Medium)
[2] (Medium)
(Increments of 1)
▶
z
Manual Iris (Fixed adjustment of
aperture)
[OFF] (no fixed
aperture)
[1] (Small)
[255] (Large)
[254] (Medium)
[2] (Medium)
(Increments of 1)
▶
z
Dynamic Gamma (adjustment of signal
compensation)
[OFF] (no automatic
compensation)
[1] (Small)
[3] (Large)
[2] (Medium)
Note
z
When [DYNAMIC GAMMA] is set [3], the contrast
will be maximized.
z
Luminance control and iris operate simultaneously,
but the iris will not operate if left fully open while