341
<Setting display example 2>
The following is an execution example of the WEB authentication page
view configuration display command.
Fig. 4-14-2
Execution example of the WEB authentication page
configuration display command
Page Title
Displays the title string of the WEB authentication
login page.
You can enter the title in Japanese using Unicode.
Logo Data
Displays the availability of logo data. You can
transfer image data in JPG/PNG/GIF format with the
size of up to 512KB via TFTP server.
You can also check the actual image in the WEB
configuration screen.
Existed
Indicates that logo data is saved.
None
Indicates that logo data is not saved.
(factory default)
User Name String
Displays a string in the user name input field.
(factory default setting: User Name)
You can enter the user name in Japanese using
Unicode.
Password String
Displays a string in the password input field.
(factory default setting: Password)
You can enter the password in Japanese using
Unicode.
Message
Displays the text shown in the Message filed.
You can enter the text in Japanese using Unicode
and use the following HTML tags. (Other HTML tags
are disabled.)
<a> <b> <i> <u> <center> <right> <left> <font> <h1>
to <h5> <div> <span> <br> <p>
Description
Displays the text shown in the Description filed.
You can enter the text in Japanese using Unicode
and use the following HTML tags. (Other HTML tags
M24eGi> enable
M24eGi# show web-authentication contents
Page Title :
Logo Data : None
User Name String : User Name
Password String : Password
Message :
Description :
M24eGi#
Содержание PN28080i
Страница 26: ...26 4 Switch Contact Shows the Switching Hub s current contact information ...
Страница 39: ...39 ...
Страница 43: ...43 ...
Страница 60: ...60 Note Parameter name Note None ...
Страница 94: ...94 Setting Range Parameter name Setting range None None Note Parameter name Note None None ...
Страница 158: ...158 Note Parameter name Note MAC addr None interface name None VLAN ID Set an existing VLAN ID ...
Страница 162: ...162 addresses ...
Страница 183: ...183 management VLAN and VLAN 10 and 20 do not ...
Страница 287: ...287 priority and used factory default setting Local The value of Re auth Period of this device is always used ...
Страница 293: ...293 ...
Страница 342: ...342 are disabled a b i u center right left font h1 to h5 div span br p ...
Страница 386: ...386 Note Parameter name Note ID None Name None PortList None ...
Страница 431: ...431 Appendix A Specifications Refer to Operation Manual Menu Screens for your Switching Hub to read the specifications ...
Страница 436: ...436 ifSpecific RO ifSpecific port_num ...