305
<Setting display example>
The following is an execution example of the IEEE802.1X MAC-based
authentication configuration display command.
Fig. 4-12-1
Execution example of the IEEE802.1X MAC-based authentication
configuration display command
NAS ID
Displays authentication ID (NAS Identifier).
Port No
Displays a port number.
Number of
Supplicant
Displays the number of supplicants on which
authentication is permitted.
The factory default setting is 512.
Operational Control
Direction
Displays the packet control status in an
unauthorized status.
Both
In an unauthorized status, the packet
transmission/reception is not executed.
In
In an unauthorized status, the packet
reception is not executed.
Administrative
Control Direction
Displays the packet control configuration in an
unauthorized status.
Both
In an unauthorized status, the packet
transmission/reception is not executed.
In
In an unauthorized status, the packet
reception is not executed.
Transmission Period
Displays the number of seconds to wait before
requesting the supplicant to reattempt
authentication.
The factory default setting is 30 seconds.
Supplicant Timeout
Displays the timeout for the client.
The factory default setting is 30 seconds.
M24eGi> enable
M24eGi# show dot1x mac-based 1
NAS ID: Nas1 Port No: 1 Number of Supplicant: 512
Operational Control Direction: Both Administrative Control Direction: Both
Transmission Period : 30 seconds Maximum Request : 2
Supplicant Timeout : 30 seconds Quiet Period : 60 seconds
Server Timeout : 30 seconds Re-authentication Period: 3600 seconds
Force Auth Timeout : 3600 seconds Per Port Re-auth : Disabled
Re-Auth Timer Mode : RADIUS
Supplicant MAC Addr Type MAC Control Auth Status Re-auth
------------------- ------- ------------------ ------------ --------
No entry exist!
M24eGi#
Содержание PN28080i
Страница 26: ...26 4 Switch Contact Shows the Switching Hub s current contact information ...
Страница 39: ...39 ...
Страница 43: ...43 ...
Страница 60: ...60 Note Parameter name Note None ...
Страница 94: ...94 Setting Range Parameter name Setting range None None Note Parameter name Note None None ...
Страница 158: ...158 Note Parameter name Note MAC addr None interface name None VLAN ID Set an existing VLAN ID ...
Страница 162: ...162 addresses ...
Страница 183: ...183 management VLAN and VLAN 10 and 20 do not ...
Страница 287: ...287 priority and used factory default setting Local The value of Re auth Period of this device is always used ...
Страница 293: ...293 ...
Страница 342: ...342 are disabled a b i u center right left font h1 to h5 div span br p ...
Страница 386: ...386 Note Parameter name Note ID None Name None PortList None ...
Страница 431: ...431 Appendix A Specifications Refer to Operation Manual Menu Screens for your Switching Hub to read the specifications ...
Страница 436: ...436 ifSpecific RO ifSpecific port_num ...