161
UF-7000/8000
APR 2007
Ver. 2.1
UF-7100/8100
011 RX Level
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
Selects the receiving sensitivity of -33/-38/-43/-48
dBm.
012 DTMF Level
00 = 0 dBm
~
15 = -15 dBm
Selects the DTMF output level, 0 to -15 dBm in 1
dBm steps.
013 G3 RX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 reception mode,
0dB, 4dB, 8dB or 12dB.
014 G3 TX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 transmission
mode, 0dB, 4dB, 8dB or 12dB.
015 ~
016
Not Used
017 TX Start
2400 bps
4800 bps
7200 bps
9600 bps
TC7200
TC9600
12000 bps
14400 bps
Selects the transmission modem start speed,
14400/12000/TC9600/TC7200/9600/7200/4800/
2400 bps.
(Press “V” or “/\ “ to select the symbol rate.)
Note:
This parameter is applicable only when
communicating with regular G3 machines. When
communicating with Super G3 (V.34) machines,
use Parameter No. 32.
018 RX Start
2400 bps
4800 bps
7200 bps
9600 bps
TC7200
TC9600
12000 bps
14400 bps
Selects the reception modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
(Press “V” or “/\ “ to select the symbol rate.)
Note:
This parameter is applicable only when
communicating with regular G3 machines. When
communicating with Super G3 (V.34) machines,
use Parameter No. 33.
019 ITU-T V.34
1 = Off
2 = On
3 = Select
Selects whether the ITU-T V.34 is Off, On or Select.
Select
: Select whether the ITU-T V.34 is Off or On,
when entering Phone Book Dialing
Numbers or Manual Number Dialing.
020 ITU-T ECM
1 = Off (Invalid)
2 = On (Valid)
Select the ECM mode.
021 EP Tone
1 = Off (without EP Tone)
2 = On (with EP Tone)
Selects whether to add the echo protect tone on
V.29 mode.
(Used when Echo Suppression is disabled.)
On
: Add
Off
: Do not add
022 Signal Interval
1 = 100 ms
2 = 200 ms
3 = 500 ms
Selects the time interval between the receiving
signal and the transmitting signal.
023 TCF Check
1 = Normal (Short)
2 = Long
Selects the TCF check interval Long/Short
024 CED Frequency
1 = 1080 Hz (non ITU-T)
2 = 2100 Hz
Selects the CED frequency 2100/1080 Hz
Function Parameter Table
No.
Parameter
Selections
Function
Содержание Panafax UF-7000
Страница 9: ...Table of Contents 9 Schematic Diagram 303 10 1 General Circuit Diagram 303 ...
Страница 122: ...122 UF 7000 8000 APR 2007 Ver 2 1 UF 7100 8100 Sensor and Switch Location ...
Страница 190: ...190 UF 7000 8000 APR 2007 Ver 2 1 UF 7100 8100 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 239: ...239 UF 7000 8000 APR 2007 Ver 2 1 UF 7100 8100 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Страница 304: ...304 APR 2007 Ver 2 1 UF 7000 8000 UF 7100 8100 memo ...
Страница 305: ...DZSD001829 14 Panasonic Software Operating Instructions Network Firmware Update Tool for Service Technicians Version 3 ...
Страница 320: ...memo ...
Страница 321: ...DZSD000965 17 Panasonic Software Operating Instructions Local Firmware Update Tool for Service Technicians Version 3 ...
Страница 332: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next ...
Страница 336: ...memo ...
Страница 373: ...memo ...
Страница 374: ...DZZSM00287 ...