164
UF-7000/8000
APR 2007
Ver. 2.1
UF-7100/8100
068 NYSE Fax
Forward
(USA and Canada
Only)
1 = Off
2 = On
Selects whether the machine will forward the
incoming and outgoing faxes to a specified station.
Note:
Once this parameter is activated, Fax
Forwarding via Fax Parameter 054 is
automatically disabled, an Access Code of
"0000" is automatically assigned and Fax
Parameter 038 has a new setting added called
"NYSE".
069 NYSE Local Print
(USA and Canada
Only)
1 = Inc
2 = On (Always)
Selects the printing condition for the incoming faxes
after FAX Forwarding.
INC.
: Prints only if FAX Forwarding fails.
ON
: Always prints.
070 Line Error
128 lines
256 lines
512 lines
1024 line
2048 lines
Off
(will not disconnect line)
1. Selects the line disconnect condition during
reception. If the number of line errors exceed this
setting, the unit will disconnect the line.
Press “V” or “/\ “ to select the symbol rate.
2. Selects the transmit condition of RTP/PIP or
RTN/PIN.
(Available if No.73 Error Detect is set to "LINES")
(See Note 1)
071 Total Error
1 = 5%
2 = 10%
3 = 15%
4 = 20%
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "RATE".)
(See Note 2)
072 Continuous Error 1 = Off (unlimited)
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
Selects the continuous total error criteria of Off/3/6
or 12 lines in Standard mode. If continuous total
error exceeds this setting, the unit will transmit
RTN/PIN.
(Available if No.73 Error Detect is set to "RATE".)
073 Error Detect
1 = Lines
2 = Rate
Selects the error detect condition Lines/Rate.
074 RTN Receive
1 = Disconnect
2 = Continue
Selects whether to disconnect the phone line or
continue when "RTN" is received.
075 Coding
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR
(MH or MR or MMR)
4 = JBIG
Selects the coding scheme.
076 Batch TX
(USA and Canada
Only)
1 = Off
2 = On
Selects whether the batch transmission is available.
077 RX JAM Length
1 = Off (unlimited)
2 = 2 m
Selects the maximum length of a received
document that can be printed.
078~
079
Not Used
080 Doc Top Feed
-99
~
+99
Adjusts the distance between the scanning sensor
ON position and the scanning start position.
081 Doc End Feed
-90
~
+127
Adjusts the distance between the scanning sensor
OFF position and the scanning end position.
Function Parameter Table
No.
Parameter
Selections
Function
Содержание Panafax UF-7000
Страница 9: ...Table of Contents 9 Schematic Diagram 303 10 1 General Circuit Diagram 303 ...
Страница 122: ...122 UF 7000 8000 APR 2007 Ver 2 1 UF 7100 8100 Sensor and Switch Location ...
Страница 190: ...190 UF 7000 8000 APR 2007 Ver 2 1 UF 7100 8100 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 239: ...239 UF 7000 8000 APR 2007 Ver 2 1 UF 7100 8100 7 Installation Refer to Quick Guide For Facsimile and Copy Functions ...
Страница 304: ...304 APR 2007 Ver 2 1 UF 7000 8000 UF 7100 8100 memo ...
Страница 305: ...DZSD001829 14 Panasonic Software Operating Instructions Network Firmware Update Tool for Service Technicians Version 3 ...
Страница 320: ...memo ...
Страница 321: ...DZSD000965 17 Panasonic Software Operating Instructions Local Firmware Update Tool for Service Technicians Version 3 ...
Страница 332: ...Local Firmware Update Tool Parallel USB Port Page 12 5b4 Firmware Code File selection is completed Click Next ...
Страница 336: ...memo ...
Страница 373: ...memo ...
Страница 374: ...DZZSM00287 ...