33
Note 1:
Function Parameter No. 070 (Line Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 2:
Function Parameter No. 071 (Total Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 3:
The default setting of parameters depends on the destination’s specifications or regulations. Print
the Function Parameter List to confirm the default settings.
090 PRINT DENSITY 1 = Normal
2 = Darker
Print Density sometimes gets light at low Humidity
condition. In this case, selects “2:Darker”.
(Except for U.S.A. and Canada)
091 Not Used
092 SMOOTHING
1 = Off
2 = On
Selects whether the smoothing function is available.
093
~
129
Not Used
130 BUSY-ACK
TIMING
(Except UF-580/
780)
• In Busy
• After Busy
• While Busy
Selects the signal timing between the BUSY and
ACK signal in Printer Interface Mode.
131 CMD RCV GRD
TIMER
(Except UF-580/
780)
1 min.
~
15 min.
Selects the Guard Timer between each GDI
Command in Printer Interface Mode.
132 PRT DATA
TIMER
(Except UF-580/
780)
1 min.
~
15 min.
Selects the Guard Timer between each GDI Data
Frame in Printer Interface Mode.
133 COLLATION
(PRT)
(Except UF-580/
780)
1 = Off
2 = On
3 = Auto
Selects the Print Collation in Printer Interface Mode.
When “Auto” is selected, print collation will operate
according to the setting in Fax Parameter #65.
134 COLLATION
(PC I/F)
(Except UF-580/
780)
1 = Off
2 = On
3 = Auto
Selects the Print Collation in PC Interface Mode.
When “Auto” is selected, print collation will operate
according to the setting in Fax Parameter #65.
135
~
199
Not Used
Signal
Setting
1:128
2:256
3:512
4:1024
5:2048
6:Off
MCF/PIP
0-31
0-63
0-127
0-255
0-511
Always
RTP/PIP
32-63
64-127
128-255
256-511
512-1023
-
RTN/PIN
64-127
128-255
256-511
512-1023
1024-2047
-
Signal
Setting
1:5%
2:10%
3:15%
4:20%
MCF/PIP
0-2
0-4
0-7
0-9
RTP/PIP
3-4
5-9
8-14
10-19
RTN/PIN
5-
10-
15-
20-
Function Parameter Table
No.
Parameter
Selections
Function