31
050 RING DETECT
MODE
1 = Normal
2 = Rough
Selects the quality of ringer detection. Use if the line
signal is out of regulation, set to "Rough" so that the
unit may detect the ringing signals.
051 Not Used
052 PULSE RATE
1 = 10 pps
2 = 20 pps
Selects the dial pulse rate 10/20 pps.
053
054
Not Used
055 BUSY TONE
CHECK
1 = Off
2 = On
Selects whether to detect the Busy Tone.
056 DIAL TONE
CHECK
(Except for USA
and Canada)
1 = Off
2 = On
Selects whether to detect dial tone before dialing the
telephone number.
057 DC LOOP
CHECK
(Except for USA
and Canada)
1 = Off (will not check)
2 = On (checks)
Selects whether the unit checks the DC Loop during
communication.
058 COMM.JRNL
+IMAGE
1 = Off (without image)
2 = On (with image)
Selects whether the machine prints the COMM.
Journal with image.
059 CONF. RCV
REPORT ON
1 = Off
2 = On
060 VERSION
Indicates the Host software
version.
061 TX/RX/PRT/CPY
COUNTER
TX/RX/PRT/CPY
Displays the transmitted, received, total printed and
copied document count.
062 PRINT
COUNTER
1 = Off
2 = On
Selects whether to print in the Fax Parameter List,
the counter information that is displayed in the
Function Parameter No. 61.
063 Not Used
064 SILENT
DETECTION
TIME OUT
01 = 1 sec.
~
60 = 60 sec.
Select silent detection timeout time (TAM I/F).
065 SILENT
INTEGRATION
TIME
01 = 1 sec.
~
10 = 10 sec.
Select ring detection integration time (TAM I/F).
066 RING COUNT
(TAM)
01 = 1 sec.
~
99 = 99 sec.
Select ring detection count 1 to 99 times in one step
intervals on TAM I/F mode.
067 Not Used
068 NYSE FAX
FORWARD
(For USA and
Canada only)
1 = Off
2 = On
Selects whether the machine will forward the
incoming and outgoing faxes to a specified station.
Note:
Once this parameter is activated, Fax Forwarding
via Fax Parameter 054 is automatically disabled.
069 NYSE LOCAL
1 = INC
2 = ON (Always)
Selects the printing condition for the incoming faxes
after FAX Forwarding.
INC.
: Prints only if FAX Forwarding fails.
ON
: Always prints.
Function Parameter Table
No.
Parameter
Selections
Function