6.2.12 Laser Unit (LSU) Control Circuit
The laser control signals are described below.
nLDEN
The LSU is activated when this output signal is LOW. If an error occurs, the nLDEN output signal level
goes High and the LSU is deactivated.
nVIDEO
This is the actual Data Signal. The Laser is ON when the nVIDEO output signal level is LOW.
nHSYNC
This horizontal synchronization signal transmitted from the Beam Detection Sensor sets the horizontal
position of the laser beam as it crosses the OPC Drum.
nSTART
This is the Scanner Motor Control Signal. The Scanner Motor rotates when the nSTART output signal
level is LOW.
nREADY
A Phased-Lock Loop (PLL) circuit keeps the Scanner Motor speed constant when the nREADY is at a
Low output signal level.
CLK
This is the Scanner Motor Clock.
+24V
LVPS
(Power Supply Unit)
+24V
+24V
Cover
+24VD
ILS PCB
Paper Feed Solenoid
Laser Unit
DC/DC
Converter
Rush Current
Protection Circuit
pMPOW
HVPS
(Power Supply Unit)
Motor
(SC PCB)
+24VM
+24VM
+24VM
+24VM
L+5V
Interlock Safety Circuit Block Diagram
Содержание Panafax UF-5300
Страница 2: ...2 ...
Страница 3: ...3 ...
Страница 5: ...5 ...
Страница 9: ...9 ...
Страница 10: ...10 ...
Страница 11: ...11 ...
Страница 12: ...12 memo ...
Страница 246: ...DZSD001829 15 Panasonic Software Operating Instructions Network Firmware Update Tool for Service Technicians Version 3 ...
Страница 259: ...Network Firmware Update Tool LAN Page 14 13 Confirm the message in the text box and click OK to close the tool or ...
Страница 260: ...DZSD000965 18 Panasonic Software Operating Instructions Local Firmware Update Tool for Service Technicians Version 3 ...
Страница 274: ...Published in Japan ...