88
4.3.6.
Information Code: 434
START
END
Is communication with the
reference unit successful?
Does the trouble occur
regardless of the remote unit?
Yes
Yes
Yes
No
Replace the SC PCB.
No
Can the transmitter in
question transmit to the
other units?
Check the remote unit in
question.
(Remote unit is defective)
Change the parameter in Service Mode 1.
(Refer to Sect. 5.1.2.)
for transmitter: #010: Increase Tx Level
for receiver : #011: Reduce Rx Sensitivity Level
The telephone line may have
a high level of white noise
and/or frequent impulse noise.
Ask the telephone company
to check the line.
No