Post Adjustment Driver (VFK0329)
1. Insert the alignment tape.
2. Press and hold VCR/TV button and CH DOWN buttons on VCR
together over 5 seconds in power off condition.
The power comes on and the unit goes into service mode.
3. Play back the alignment tape.
4. To enter Tracking center mode, press PLAY button in Play back
mode. "TRACKING CENTER" will be displayed on the TV monitor.
5. Connect the oscilloscope to TP3002 on the Video Signal Process
Section of the Main C.B.A. Use TP6205 as a trigger.
6. Confirm that the RF envelope is flat enough (V1/V-max. is 0.7 or
more). If not, with Post Adjustment Driver, adjust P2 and P3 post
height so that the envelope waveform becomes as flat (V1/V-
max.is 0.7 or more) as possible (No envelope drop). If the
envelope drop appears on the left-half of the waveform, adjust P2
post height. If the envelope drop appears on the right-half of the
waveform, adjust P3 post height.
CAUTION:
Overtightening P2 and P3 posts may cause the threads to strip.
Note:
It will be possible to confirm Step 6 according to following steps.
A. Release the Tracking center mode.
B. Press the Tracking Control Up or Down button on remote
control. Make sure that the envelope waveform remains flat. If
not, readjust P2 and/or P3 post heights.
Fig. M4-1
Fig. M4-2
Содержание OmniVision PV-QV200
Страница 24: ...5 2 2 Inner Parts Location Fig J1 1 ...
Страница 25: ...5 2 3 EJECT Position Confirmation Fig J1 2 ...
Страница 26: ...5 2 4 Grounding Plate Unit Full Erase Head and Cylinder Unit Fig J2 1 ...
Страница 40: ...5 3 CASSETTE UP ASS Y SECTION 5 3 1 Top Plate Wiper Arm Unit and Holder Unit Fig K1 1 ...
Страница 86: ...10 2 MECHANISM BOTTOM SECTION ...
Страница 87: ...10 3 CASSETTE UP COMPARTMENT SECTION ...
Страница 88: ...10 4 CHASSIS FRAME AND CASING PARTS SECTION ...
Страница 89: ...10 5 PACKING PARTS AND ACCESSORIES SECTION ...
Страница 117: ...R3036 ERJ6GEYJ122V MGF CHIP 1 10W 1 2K ...
Страница 123: ...ECKATS101MB CERAMIC 20 250V 100P ...
Страница 125: ...C3021 ECUV1C224ZFV C CHIP 80 20 16V 0 22 ...