CAUTION
1. Check grounding before checking for trouble.
2. Be careful of high voltage circuit.
3. Discharge high voltage capacitor.
4. When checking the continuity of the switches or the high voltage transformer,disconnect one lead wir
from these parts and then check continuity with the AC plug removed. To do otherwise may result in a
false reading or damage to your meter. / When disconnecting a plastic connector from a terminal, you
must hold the plastic connector instead of the lead wire and then disconnect it, otherwise lead wire m
be damaged or the connector cannot be removed.
5. Do not touch any parts of the circuitry on the digital programmer circuit, since static electric discharge
may damage this control panel. / Always touch yourself to ground while working on this panel to
discharge any static charge in your body.
6. 120V AC is present on the digital programmer circuit (Terminals of power relay's and primary circuit of
low voltage transformer). When troubleshooting, be cautious of possible electrical shock hazard.
First of all operate the microwave oven following the correct operating procedures in order to find the
exact cause of any trouble.
SYMPTOM
CAUSE
CORRECTIONS
1. Oven is dead.
1.
2.
3.
4.
Open or loose lead wire harness
Open thermal cutout (Magnetron)
Open low voltage transformer
Defective DPC
Check fan motor when thermal
cutout is defective.
Fuse is OK.
No display and no operation
at all.
2. No display and no operation
at all. / Fuse is blown.
1.
2.
Shorted lead wire harness
Defective primary latch switdh
(NOTE 1)
Check adjustment of primary,
secondary latch switch and sh
switch including door.
3. Defective short switch (NOTE 1)
4. Defective Inverter Power Supply (U)
Refer to component test procedure
Refer to Inverter PCB
Troubleshooting.
NOTE 1:
All of these switches must be replaced at the same time.
Check continuity of power relay B (RY-1)'s contacts (between 1 and 2
and if it has continuity, replace power relay B (RY-1) also.
3. Oven does not accept key
input(Program)
1.
2.
Key input is not insequence
Open or loose connection of
membrane key pad to DPC (Flat
cable)
Refer to operation procedure.
3. Shorted or open membrane key
board
4. Defective DPC
Refer to DPC troubleshooting.
4. Fan motor turn on when
oven is plugged in with door
closed.
3. Misadjustment or loose wiring of
secondary latch switch
Adjust door and latch switches
4. Defective secondary latch switch
35
Содержание NN-P295
Страница 3: ...3 ...
Страница 4: ...4 ...
Страница 5: ...5 ...
Страница 6: ...1 SCHEMATIC DIAGRAM 1 1 APH NN P295 H275 1 2 APH NN S255 6 ...
Страница 7: ...1 3 APH NN H264 FR S254 FR 7 ...
Страница 8: ...1 4 CPH NN P295 H275 8 ...
Страница 9: ...1 5 CPH NN S255 S245 9 ...
Страница 10: ...2 MEASUREMENTS AND ADJUSTMENTS 10 ...
Страница 19: ...40 F607V6Z00AP LAMP COVER U 1 19 ...
Страница 30: ...30 ...
Страница 31: ...7 2 NN H275 APH CPH NN S255 APH CPH 31 ...
Страница 32: ...32 ...
Страница 33: ...7 3 NN S245 CPH H264 FR APH S254 FR APH 33 ...
Страница 34: ...34 ...
Страница 35: ...7 4 PARTS LIST 7 4 1 NN P295 APH CPH S255 APH CPH 35 ...
Страница 44: ...reserved Unauthorized copying and distribution is a violation of law 2 ...
Страница 45: ...3 ...
Страница 46: ...4 ...
Страница 47: ...5 ...
Страница 49: ...3 CONTROL PANEL CPH 7 ...
Страница 50: ...4 OPERATION AND DIGITAL PROGRAMMER CIRCUIT TEST PROCEDURE 4 1 To set clock 8 ...
Страница 55: ...6 SCHEMATIC DIAGRAM CPH 13 ...
Страница 76: ...13 TROUBLESHOOTING GUIDE 34 ...
Страница 81: ...13 3 How to check the semiconductors using an OHM meter 14 EXPLODED VIEW AND PARTS LIST 39 ...
Страница 89: ...20 DIGITAL PROGRAMMER CIRCUIT SCHEMATIC DIAGRAM 47 ...
Страница 90: ...21 DIGITAL PROGRAMMER CIRCUIT PARTS LIST 48 ...