RATED OUTPUT
TEMPERATURE RISE
1100W
Min. 16.9°F(9.4°C)
1200W
Min. 18.5°F(10.3°C)
3. PROCEDURE FOR MEASURING MICROWAVE
ENERGY LEAKAGE
WARNING
Check for radiation leakage after every servicing.
Should the leakage be more than 2 mW/cm
2
(1mW/
cm
2
for Canada) inform PASC, PSC, or PCI
immediately. After repairing or replacing any
radiation safety device, keep a written record for
future reference, as required by D.H.H.S. and Health
and Welfare Canada regulation. This requirement
must be strictly observed. In addition, the leakage
reading must be recorded on the service repair
ticket while in the customer’s home.
NOTE:
The U.S. Government standard is 5 mW/cm
2
while in the customer’s
home. 2mW/cm
2
stated here is our own voluntary standard. (1mW/
cm
2
for Canada)
3.1. Equipment
- Electromagnatic radiation monitor
- Glass thermometer 212°F or 100°C
- 600cc glass beaker
3.2. Procedure for measuring radiation leakage
Note before measuring.
- Do not exceed meter full scale deflection. Leakage monitor should
initially be set to the highest scale.
- To prevent false readings the test probe should be held by the grip
portion of the handle only and moved along the shaded area in
Figure no faster than 1 inch/sec (2.5cm/sec).
- Leakage with the outer panel removed ...... less than 5mW/cm
2
.
- Leakage for a fully assembled oven with door normally closed ......
less than 2mW/cm
2
(1mW/cm
2
for Canada).
- Leakage for a fully assembled oven [Before the latch switch
(primary) is interrupted] while pulling the door ...... less than 2mW/
cm
2
.
13
Содержание NN-P295
Страница 3: ...3 ...
Страница 4: ...4 ...
Страница 5: ...5 ...
Страница 6: ...1 SCHEMATIC DIAGRAM 1 1 APH NN P295 H275 1 2 APH NN S255 6 ...
Страница 7: ...1 3 APH NN H264 FR S254 FR 7 ...
Страница 8: ...1 4 CPH NN P295 H275 8 ...
Страница 9: ...1 5 CPH NN S255 S245 9 ...
Страница 10: ...2 MEASUREMENTS AND ADJUSTMENTS 10 ...
Страница 19: ...40 F607V6Z00AP LAMP COVER U 1 19 ...
Страница 30: ...30 ...
Страница 31: ...7 2 NN H275 APH CPH NN S255 APH CPH 31 ...
Страница 32: ...32 ...
Страница 33: ...7 3 NN S245 CPH H264 FR APH S254 FR APH 33 ...
Страница 34: ...34 ...
Страница 35: ...7 4 PARTS LIST 7 4 1 NN P295 APH CPH S255 APH CPH 35 ...
Страница 44: ...reserved Unauthorized copying and distribution is a violation of law 2 ...
Страница 45: ...3 ...
Страница 46: ...4 ...
Страница 47: ...5 ...
Страница 49: ...3 CONTROL PANEL CPH 7 ...
Страница 50: ...4 OPERATION AND DIGITAL PROGRAMMER CIRCUIT TEST PROCEDURE 4 1 To set clock 8 ...
Страница 55: ...6 SCHEMATIC DIAGRAM CPH 13 ...
Страница 76: ...13 TROUBLESHOOTING GUIDE 34 ...
Страница 81: ...13 3 How to check the semiconductors using an OHM meter 14 EXPLODED VIEW AND PARTS LIST 39 ...
Страница 89: ...20 DIGITAL PROGRAMMER CIRCUIT SCHEMATIC DIAGRAM 47 ...
Страница 90: ...21 DIGITAL PROGRAMMER CIRCUIT PARTS LIST 48 ...