No. SX-DSV02310 - 47 -
R2.0 Motor
Business
Division,
Appliances Company, Panasonic Corporation
5-2 NOP command (Command code: 0
h)
This is for the temporary transmission of invalid data after the network has been established.
Never use this command for any other purpose.
The servo driver will control based on the previous command.
Control bits (Byte 2–3) are also invalid (previous data is retained).
If NOP command is transmitted in servo-on state, the control bit is disabled, inhibiting servo off.
Command
Response
Byte bit7
6
5
4
3
2
1
0
Byte
bit7
6
5
4
3
2
1
0
0
C
(0)
Update_Counter
MAC-ID
0
R
(1)
Update_Counter
_Echo
Actual_MAC-ID
1
TMG_
CNT
Command_Code (00h)
1
CMD_
Error
Command_Code_Echo (00h)
2
2
3
Optional
3
Status_Flags
4 L
4 L
5 ML
5 ML
6 MH
6 MH
Cyclic
7
<Command_Data1>
Optional
H
7
<Response_Data1>
Default: Actual_Position (APOS)
[Command unit]
H
8 L
8 L
9 ML
9 ML
10 MH
10 MH
11
<Command_Data2>
Optional
H
11
<Response_Data2>
Default: Actual_Speed (ASPD)
[Command unit/s] or [
mm/s
]
H
12 L
12 L
13 ML
13 ML
14 MH
14 MH
Non-
cyclic
15
<Command_Data3>
Optional
H
15
<Response_Data3>
Default:
Thrust
(TRQ)
[0.1%]
H
Title
Command
Response
<Response_Data1>
Actual_Position
(APOS)
–
Default: Motor actual position
[Size]: Signed 32-bit
[Unit]: Command unit
<Response_Data2>
Actual_Speed
(ASPD)
–
Default: Motor actual speed
[Size]: Signed 32-bit
[Unit]: Setting value of Pr.7.25 (RTEX speed unit setup)
Pr.7.25
Unit
0 [
mm/s
]
1 [Command
unit/s]
<Response_Data3>
Thrust
(TRQ)
–
Default: Instruction thrust to motor
[Size]: Signed 32-bit
[Unit]: 0.1%
▪
For selection method of Response_Data 1/2/3, see 4-3-1.