background image

   

  

 

9

VIP

®

 Series Green Features

Noise Reduction

Ultra-low freezers are often located 
within research and hospital laboratories 
or production facilities. Users prefer 
close proximity for easy access to valu-
able stored products.

If operating noise from refrigeration 
compressors is excessive, and/or com-
pounded by installation of multiple freez-
ers in adjacent locations, the working 
environment is severely compromised. 

Panasonic has included advanced noise 
abatement in all contemporary ultra-low 
freezers and noise reduction levels are 
well below those of competitive freez-
ers. Data is available upon request.

Panasonic Refrigeration Delivers 
Uniform Temperature

The Panasonic cascade refrigeration 
system uses Panasonic designed 
compressors for high-performance, reli-
ability and peace of mind. Refrigeration 
components are carefully selected and 
matched for optimum operation under 
demanding laboratory environments.
• Increased reserve cooling capacity 

improves temperature recovery after 

door openings.

• Quieter operation is achieved  

through condenser fan blade design, 

noise abatement insulation and anti-

vibration mounts.

• Voltage boost and surge protection  

devices permit dependable operation 

over wider power ranges and environ-
mental conditions. 

(Except MDF-U76VA)

Electrical Standards

All Panasonic products including ultra-
low temperature freezers are tested 
and certified by an NRTL (National 
Recognized Testing Laboratory) to assure 
compliance with US and International 
standards for electrical safety prescribed 
in 29 CFR 1910.7( c ). 

Water Cooled Option (MDF-WCL)

Now a water cooled condenser option 
is available for facilities equipped with 
water recirculation cooling systems.  
This option utilizes the cascade refrig-
eration design to reuse the energy 
produced by an ultra low freezer while 
delivering energy-savings and high  
performance cooling.

Ideal for material storage in repositories, 
hospitals, clinics and medical research 
facilities, the water cooled system is 
designed to significantly reduce energy 
consumption.
• Energy efficiency  
• Cost saving
• Re-use of energy
• Faster recovery time
• Improved sample security

Inventory Management

The concept of High Density Storage 
is enabled by advances in Panasonic 
Cool Safe compressor design. The cost 
per 2” box of interior storage space is 
significantly lower in a Panasonic ultra-
low freezer, generating immediate return 
on investment based on first costs, 
operating costs and maintenance costs 
over time.

Additionally, the placement of evaporator 
surfaces within the cabinet walls achieve 
exceptional documented ultra-low tem-
perature uniformity, thereby permitting 
investigators more freedom in placing 
valuable cell lines and biologicals within 
the interior cabinet, and assuring uniform 
cell viability when harvesting products 
from the ultra-low archive.

Because benefits of the Panasonic Cool 
Safe compressor design extend to evap-
orator tubing surrounding the interior 
chamber, and the interior chamber is part 
of the thin-wall composite based on the 
patented VIP

®

 vacuum insulation panel 

cabinet, Panasonic can offer more usable 
storage volume within the same sq.ft. of 
floor space than competitive models.

Phase 1 

Heat generated from the freezer compartment is trans-
ferred to a water circuit using a plate heat exchanger

Phase 2 

Transport the absorbed heat/energy 

Phase 3 

Able to re-use heat/energy on other heat/energy 
demanding systems.

Water Cooled Option (MDF-WCL) How It Works

Applies to MDF-U33V, MDF-U53VA, MDF-U56VC, MDF-U76VC, MDF-U76VA

Содержание MDF-U33V

Страница 1: ...olution VIP Series www panasonic com biomedical Features Industry leading 86 C preservation for uniformity reliability and optimized footprint Panasonic Cool Safe refrigeration system designed to deliver energy saving high performance cooling 86 C Ultra Low Freezers Panasonic the new name for SANYO ...

Страница 2: ...stem Automatic Alarm System Energy SAVE Air Filter Insulated Inner Doors ICD Digital Display Remote Alarm CPU and Touch Pad ree VIP Vacuum Insulation Panel VIP Quiet Reliable Compressor Cascade Cooling System ce c em ble Energy SAVE Air Filter VIP Plus Vacuum Insulation Panel VIP Filterless Design Insulated Inner Doors ICD Digital Display Remote Alarm CPU and Touch Pad Free VIP Vacuum Insulation P...

Страница 3: ...he heat exchanger through an improved new design incor porating more surface area contact at critical points in the refrigeration system we are able to improve the overall ef ficiency and reduce compressor running time This along with other improve ments to heat exchanger in the refrigera tion system translates to a substantial increase in energy efficiency 1 Applies to models MDF U53VA MDF U56VC ...

Страница 4: ...tatic condenser filter for routine condenser air filter cleaning 7 High impact recessed casters and leveling feet simplify installation 8 New generation Panasonic designed Cool Safe compressors are specifi cally designed for low temperature applications 9 Multiple access ports permit inser tion of independent probes instru mentation or liquid N2 or liquid CO2 back up injectors 10 Commercially avai...

Страница 5: ...high impact polyurethane with newly developed foamed in place insulation and minimize exposure during routine door openings Dual inner door configuration stan dard with optional half inner door ac cessories available for field installation For a four door configuration order two sets of half inner doors A universal keyed door lock prevents the outer door from opening The two primary compartments c...

Страница 6: ...roughout the high and low stage circuits transmit information to the Panasonic Status Alert central controller for operation monitoring interpretation and component protection High Stage Capillary Tube Liquid refrigerant under pressure is passed through the capillary tube where it flash evaporates in the interstage heat exchanger to absorb energy heat from the low stage refrigerant circuit High St...

Страница 7: ...ed control overlay The panel is door mounted and angled for easy access Alarm indicator lamp glows when freezer is in alarm condition alarm ringback is factory set for 30 minutes adjustable in 10 minute increments from 10 to 60 minutes Panasonic exclusive Ni MH battery powers control memory and alarm functions during power failure Status alert function uses predictive intelligence to determine if ...

Страница 8: ...nergy manage ment to solar power and alternative energies Panasonic remains committed to providing the best possible labora tory equipment for research Uniformity Performance The placement of evaporator surfaces within the cabinet walls achieve excep tional documented ultra low temperature uniformity thereby permitting investiga tors more freedom in placing valuable cell lines and biologicals with...

Страница 9: ...er recirculation cooling systems This option utilizes the cascade refrig eration design to reuse the energy produced by an ultra low freezer while delivering energy savings and high performance cooling Ideal for material storage in repositories hospitals clinics and medical research facilities the water cooled system is designed to significantly reduce energy consumption Energy efficiency Cost sav...

Страница 10: ...ith locking rod SUMPR 612 LR SUMPR 612 LR SUMPR 612 LR 108 standard plates with cover lid per rack Capacity 6 Capacity 8 Capacity 24 R L 1 1 6 R P M U S d o r g n i k c o l h t i w s e t a l p o r c i m r o f k c a R y r o t n e v n I 8 y t i c a p a C k c a r r e p d i l r e v o c h t i w s e t a l p d r a d n a t s 6 9 Inventory Rack for microplates with locking rod SUMPR 616 LR 60 standard plat...

Страница 11: ...Cooled Option Features Description Water Pressure Temperature Maximum Water Pressure 150psig Minimum Water Pressure Differential 15psig Maximum Water Temperature 30 C Connections Typically compression fittings on inlet and outlet but can be customized for customer needs Required Water Flow Rate Maximum Tower Water 11 4 liters per minute Installation Qualified technician required at time of install...

Страница 12: ... 630 x 600 x 1380 mm 24 8 x 23 6 x 55 1 630 x 600 x 1400 mm 34 2 x 23 6 x 55 1 870 x 600 x 1400 mm 34 2 x 23 6 x 55 1 870 x 600 x 1400 mm Exterior w x f b x h 26 4 x 34 1 x 73 2 670 x 867 x 1860 mm 30 3 x 34 4 x 78 3 770 x 870 x 1990 mm 30 3 x 34 4 x 78 3 770 x 870 x 1990 mm 39 8 x 34 4 x 78 3 1010 x 870 x 1990 mm 39 8 x 34 4 x 78 3 1010 x 870 x 1990 mm Net Weight Empty 562 lbs 255 kg 660 lbs 299 ...

Отзывы: