11
Maximum Sample Storage Capacity
Description
Model Number
MDF-U33V-PA
MDF-U53VA-PA
MDF-U56VC-PA
MDF-U76VC-PA
MDF-U76VA-PA
Individual Storage Rack System
Catalog Number
Catalog Number
Catalog Number
Catalog Number
Catalog Number
Microplate Storage Racks
(Plates Not Included)
Inventory Rack for Microplates, with locking rod;
108 Standard Plates with Cover Lid Per Rack
SUMPR-612-LR
Capacity 6
SUMPR-612-LR
Capacity 8
SUMPR-612-LR
Capacity 8
SUMPR-612-LR
Capacity 24
SUMPR-612-LR
Capacity 24
Inventory Rack for Microplates, with locking rod;
96 Standard Plates with Cover Lid Per Rack
SUMPR-611-LR
Capacity 8
SUMPR-611-LR
Capacity 8
Inventory Rack for Microplates, with locking rod;
60 Standard Plates with Cover Lid Per Rack
SUMPR-616-LR
Capacity 6
Fiberboard Storage Boxes and Dividers
Inventory Box, 2” high (2ml sample)
with 100-Cell Divider
B2C-S100
B2C-S100
B2C-S100
B2C-S100
B2C-S100
Inventory Box, 3” high (4ml sample)
with 100-Cell Divider
B3C-S100
B3C-S100
B3C-S100
B3C-S100
B3C-S100
Inventory Box, 2” high (2ml sample)
without Divider
B2C
B2C
B2C
B2C
B2C
Inventory Box, 3” high (4ml sample)
without Divider
B3C
B3C
B3C
B3C
B3C
Box Divider, 81-Cell
D81
D81
D81
D81
D81
Box Divider, 64-Cell
D64
D64
D64
D64
D64
VIP
®
Series Door Configuration
Options & Accessories
Water Cooled Option Features
Description
Water Pressure & Temperature
Maximum Water Pressure: 150psig, Minimum Water Pressure Differential: 15psig, Maximum Water Temperature: 30°C
Connections
Typically ½” compression fittings on inlet and outlet but can be customized for customer needs
Required Water Flow Rate
(Maximum)
Tower Water: 11.4 liters per minute
Installation
Qualified technician required at time of installation to balance water flow requirements. Efficiencies can be easily obtained
regarding water usage by balancing the water flow to optimum usage and freezer efficiency dependent upon the specific site
installation
Accessory
Description
Catalog Number
Half Inner Door
Set of two; Field Installed; replaces half inner door;
for a four-door configuration order two sets
MDF-5ID-PW (MDF-U53VA), MDF-5ID1-PW (MDFU-56VC),
MDF-7ID1-PW (MDF-U76VC / MDF-U76VA)
Digital Temperature Recorder
Auxiliary Data Logger
HAMSTERDT2
Liquid CO
2
Back-Up System
Auxiliary tank back in event of power failure
CVK-UB2(I)-PW
Liquid N
2
Back-Up System
Auxiliary tank back in event of power failure
CVK-UBN2-PW
Chart Recorder
Circular Chart Temperature Recorder, 7 Day
MTR-C954
Chart Paper
6” Diameter, 7 Day Chart
C7100386REV
Replacement Pen, Red / Blue
Felt tip pens, 6 per pack
R252 / R253
Digital Touch Panel Recorder
Programmable digital temperature recorder
FT560SN
Data Logging Software
For use with touch panel recorder
A016
21 CFR Part 11 Compliant Software
For use with touch panel recorder
A026