background image

   

  

 

5

0

2

4

6

8

10

12

Footprint Comparison (sq.ft.)

9.9

9.5

11.4

Footprint Comparison (sq.ft.)

Patented VIP

®

 PLUS Insulation

3

The Panasonic Patented VIP

®

 Vacuum 

Insulation Panel thin-wall composite is a 
high-efficiency design that yields more 
interior storage volume in a conventional 
freezer footprint. The VIP

®

 minimizes 

energy transfer to and from the ultra-low 
temperature interior. The composite con-
struction, complete with reflective bar-
rier film and structural closed-cell foam, 
is used on all walls and the outer door. 

This advanced insulation technology 
offers structural stability to eliminate 
distortion, and inhibits moisture accumu-
lation that can lead to icing. Aggregate 
insulation efficiency minimizes compres-
sor cycle run-time to lower energy costs.

3

Applies to models MDF-U56VC, MDF-U76VC, MDF-U76VA

VIP

®

 Series Design

Cabinet Construction 

The cabinet features a patented Pana-
sonic VIP

®

 vacuum insulated panel 

design which optimizes interior volume 
in the smallest footprint possible. The 
high-tech, composite thin-wall cellular 
construction combines the vacuum 
panel insulation with polyurethane foam 
for structural stability and high insulation 
values to minimize energy use.

• 

The outer door closes uniformly 
against a multi-point gasket to form a 
tight seal and prevent moisture migra-
tion leading to frost or ice build-up. 
Door gaskets are multi-point com-
pression for a long-lasting, tight seal 
around the periphery of the cabinet 
thermal break.

• 

An Easy-In/Easy-Out outer door latch 
permits one-handed operation. 

• 

A locking provision is designed for use 
with a conventional padlock.

• 

The interior inventory system is based 
on a center shelf and two latching 
insulated inner doors designed for one-
handed operation. 

• 

Insulated inner doors are steel-framed, 
high-impact polyurethane with newly 
developed foamed-in-place insulation 
and minimize exposure during routine 
door openings. 

• 

Dual inner door configuration (stan-
dard), with optional half-inner door ac-
cessories available for field-installation. 
For a four-door configuration order two 
sets of half inner doors.

• 

A universal keyed door lock prevents 
the outer door from opening.

• 

The two primary compartments can be 
sub-divided by adjustable shelves to 
accommodate standard stainless steel 
inventory racks for 2” or 3” boxes 
(see Accessories). Shelf brackets are 
incrementally adjustable.

• 

Rounded interior corners enhance 
temperature uniformity and simply 
cleaning and decontamination when 
required.

• 

Multiple access ports permit use of 
back-up injection tubes, probes, leads 
or instrumentation.

Superior Footprint

The center 
shelf forms 
the base of 
a convenient 
and flexible 
inventory 
system using 

conventional racks with boxes, micro-
plates or other storage protocols. Stain-
less steel shelf and insulated inner-door 
combinations create choices of interior 
compartments that can be arranged 
for long-term, low access biologicals or 
short-term, frequently accessed mate-
rial. (Inner door option can affect overall 
uniformity)(Inner door not available on 
MDF-U33V). 

• 

Easy-In/Easy Out Panasonic ‘Eagle 
Beak’ inner door latches feature  
ergonomic design to seal firmly 
against the cabinet with one hand.

• 

High strength, insulated inner doors 
help minimize change in interior 
temperatures during routine door 
openings.

• 

Additional half-door configuration per-
mits additional inner door orientations. 
Half doors are available in pairs only. 
See Accessories.

Panasonic Inner 
Door Latches 
provide single-hand 
access. The outer 
door latch closes 
smoothly with a 
single-hand action 
over a cam action 
bearing.

Barrier Film

VIP

®

 Panel

Interior

Rigid foamed  

polyurethane

Panasonic VIP Series offers maximum storage  
volume with the smallest footprint.

Footprint Comparison

(sq.ft.)

Panasonic

 

Brand A

Brand B

Содержание MDF-U33V

Страница 1: ...olution VIP Series www panasonic com biomedical Features Industry leading 86 C preservation for uniformity reliability and optimized footprint Panasonic Cool Safe refrigeration system designed to deliver energy saving high performance cooling 86 C Ultra Low Freezers Panasonic the new name for SANYO ...

Страница 2: ...stem Automatic Alarm System Energy SAVE Air Filter Insulated Inner Doors ICD Digital Display Remote Alarm CPU and Touch Pad ree VIP Vacuum Insulation Panel VIP Quiet Reliable Compressor Cascade Cooling System ce c em ble Energy SAVE Air Filter VIP Plus Vacuum Insulation Panel VIP Filterless Design Insulated Inner Doors ICD Digital Display Remote Alarm CPU and Touch Pad Free VIP Vacuum Insulation P...

Страница 3: ...he heat exchanger through an improved new design incor porating more surface area contact at critical points in the refrigeration system we are able to improve the overall ef ficiency and reduce compressor running time This along with other improve ments to heat exchanger in the refrigera tion system translates to a substantial increase in energy efficiency 1 Applies to models MDF U53VA MDF U56VC ...

Страница 4: ...tatic condenser filter for routine condenser air filter cleaning 7 High impact recessed casters and leveling feet simplify installation 8 New generation Panasonic designed Cool Safe compressors are specifi cally designed for low temperature applications 9 Multiple access ports permit inser tion of independent probes instru mentation or liquid N2 or liquid CO2 back up injectors 10 Commercially avai...

Страница 5: ...high impact polyurethane with newly developed foamed in place insulation and minimize exposure during routine door openings Dual inner door configuration stan dard with optional half inner door ac cessories available for field installation For a four door configuration order two sets of half inner doors A universal keyed door lock prevents the outer door from opening The two primary compartments c...

Страница 6: ...roughout the high and low stage circuits transmit information to the Panasonic Status Alert central controller for operation monitoring interpretation and component protection High Stage Capillary Tube Liquid refrigerant under pressure is passed through the capillary tube where it flash evaporates in the interstage heat exchanger to absorb energy heat from the low stage refrigerant circuit High St...

Страница 7: ...ed control overlay The panel is door mounted and angled for easy access Alarm indicator lamp glows when freezer is in alarm condition alarm ringback is factory set for 30 minutes adjustable in 10 minute increments from 10 to 60 minutes Panasonic exclusive Ni MH battery powers control memory and alarm functions during power failure Status alert function uses predictive intelligence to determine if ...

Страница 8: ...nergy manage ment to solar power and alternative energies Panasonic remains committed to providing the best possible labora tory equipment for research Uniformity Performance The placement of evaporator surfaces within the cabinet walls achieve excep tional documented ultra low temperature uniformity thereby permitting investiga tors more freedom in placing valuable cell lines and biologicals with...

Страница 9: ...er recirculation cooling systems This option utilizes the cascade refrig eration design to reuse the energy produced by an ultra low freezer while delivering energy savings and high performance cooling Ideal for material storage in repositories hospitals clinics and medical research facilities the water cooled system is designed to significantly reduce energy consumption Energy efficiency Cost sav...

Страница 10: ...ith locking rod SUMPR 612 LR SUMPR 612 LR SUMPR 612 LR 108 standard plates with cover lid per rack Capacity 6 Capacity 8 Capacity 24 R L 1 1 6 R P M U S d o r g n i k c o l h t i w s e t a l p o r c i m r o f k c a R y r o t n e v n I 8 y t i c a p a C k c a r r e p d i l r e v o c h t i w s e t a l p d r a d n a t s 6 9 Inventory Rack for microplates with locking rod SUMPR 616 LR 60 standard plat...

Страница 11: ...Cooled Option Features Description Water Pressure Temperature Maximum Water Pressure 150psig Minimum Water Pressure Differential 15psig Maximum Water Temperature 30 C Connections Typically compression fittings on inlet and outlet but can be customized for customer needs Required Water Flow Rate Maximum Tower Water 11 4 liters per minute Installation Qualified technician required at time of install...

Страница 12: ... 630 x 600 x 1380 mm 24 8 x 23 6 x 55 1 630 x 600 x 1400 mm 34 2 x 23 6 x 55 1 870 x 600 x 1400 mm 34 2 x 23 6 x 55 1 870 x 600 x 1400 mm Exterior w x f b x h 26 4 x 34 1 x 73 2 670 x 867 x 1860 mm 30 3 x 34 4 x 78 3 770 x 870 x 1990 mm 30 3 x 34 4 x 78 3 770 x 870 x 1990 mm 39 8 x 34 4 x 78 3 1010 x 870 x 1990 mm 39 8 x 34 4 x 78 3 1010 x 870 x 1990 mm Net Weight Empty 562 lbs 255 kg 660 lbs 299 ...

Отзывы: