Panasonic MDF-U33V Скачать руководство пользователя страница 8

   

8      

VIP

®

 Series -86°C Ultra-Low Freezers    

www.panasonic.com/biomedical

Panasonic freezers help the environment  
by reducing carbon footprint*.

VIP

®

 Series Comparative Energy Performance

*Based on internal performance data. Tested in 25°C ambient environment. Freezer cycling at -80°C. Cabinet volume, 25.7 cu. ft. Average cabinet temperature based on 
temperature mapping (15 thermocouples).

Panasonic freezers emit less heat into the 
laboratory, minimizing air conditioning costs*.

Panasonic freezers provide reduced operational  
cost for highly efficient sample storage*.

Panasonic

 

MDF-U76VC

Brand A
Brand B

Panasonic VIP

®

 Series Green  

Initiative Program

With a capacity of up to 57,600  
two-inch vials in fiberboard boxes,  
the energy-saving advantages of this  
efficient Panasonic system extend to  
lower per-unit storage costs regardless 
of the preferred inventory configuration.

Eco  Friendly Technology

• Panasonic freezers are designed to  

support LEED certification associated 

with the U.S. Green Building Council 

recommendations.

• Components are compliant with  

RoHS directives on the use of hazard-

ous materials in electrical and elec-

tronic equipment.

• Noise reduction and operating cost 

efficiencies are integrated into the 

refrigeration system.

• Heat output is limited to minimize the 

impact on facility HVAC demands.

• A microprocessor controller oversees 

the refrigeration system to regulate 

cooling cycles, reducing energy  

consumption.

• Panasonic Cool Safe compressor  

technology for lower compressor  

heat internally and externally lower 

HVAC loads.

Panasonic is conscious of the need to 
protect our environment and conserve 
energy. As a corporate pioneer in life  
science laboratory equipment and  
appliances, and as a global source of  
solutions ranging from energy manage-
ment to solar power and alternative  
energies, Panasonic remains committed  
to providing the best possible labora- 
tory equipment for research.

Uniformity Performance

The placement of evaporator surfaces 
within the cabinet walls achieve excep-
tional documented ultra-low temperature 
uniformity, thereby permitting investiga-
tors more freedom in placing valuable 
cell lines and biologicals within the 
interior cabinet, and assuring uniform 
cell viability when harvesting products 
from the ultra-low archive.

HCFC Free Refrigerants

Panasonic was the first ultra-low freezer 
manufacturer to employ environmentally 
friendly R508 low-stage refrigerant, now 
recognized as today’s industry standard 
and widely available. This non-proprietary 
refrigerant is available to refrigera-
tion service professionals on the open 
market.

The high stage R404 refrigerant is  
readily available to refrigeration profes-
sionals on the open market as well.

Because modern laboratories are energy-intensive, Panasonic has developed a corporate-wide energy savings and 
environmental impact approach to new product development. The VIP

®

 Series freezers offer significant benefits  

through a balance of refrigeration power, cabinet construction and simple to use intelligent control over all functions.

VIP

®

 Series Green Features

0

.01

.02

.03

.04

.035

.026

.038

KW

 / 

da

y / 

bo

ca

paci

ty

Power Consumption By Capacity

(KW/day/box capacity)

SANYO freezers provide reduced operational 

cost for highly efficient sample storage.

up

31

%

to

more 

efficient

0

1

2

3

4

5

4.33

2.99

4.05

Po

un

ds

 / 

Bo

Ca

paci

ty

Annual CO

2

 Emissions

by Box Capacity

SANYO freezers help the environment by

reducing carbon footprint.

up

31

%

to

less 

emissions

0.0

0.3

0.6

0.9

1.2

1.5

$1.38

$0.95

$1.29

Do

llar

s / 

Bo

Ca

paci

ty

Total Annual Operating Cost 

by Box Capacity

Cost is an average for operating freezer.  

SANYO freezers emit less heat into the laboratory, 

minimizing air conditioning costs.

up

31

%

to

less cost

Содержание MDF-U33V

Страница 1: ...olution VIP Series www panasonic com biomedical Features Industry leading 86 C preservation for uniformity reliability and optimized footprint Panasonic Cool Safe refrigeration system designed to deliver energy saving high performance cooling 86 C Ultra Low Freezers Panasonic the new name for SANYO ...

Страница 2: ...stem Automatic Alarm System Energy SAVE Air Filter Insulated Inner Doors ICD Digital Display Remote Alarm CPU and Touch Pad ree VIP Vacuum Insulation Panel VIP Quiet Reliable Compressor Cascade Cooling System ce c em ble Energy SAVE Air Filter VIP Plus Vacuum Insulation Panel VIP Filterless Design Insulated Inner Doors ICD Digital Display Remote Alarm CPU and Touch Pad Free VIP Vacuum Insulation P...

Страница 3: ...he heat exchanger through an improved new design incor porating more surface area contact at critical points in the refrigeration system we are able to improve the overall ef ficiency and reduce compressor running time This along with other improve ments to heat exchanger in the refrigera tion system translates to a substantial increase in energy efficiency 1 Applies to models MDF U53VA MDF U56VC ...

Страница 4: ...tatic condenser filter for routine condenser air filter cleaning 7 High impact recessed casters and leveling feet simplify installation 8 New generation Panasonic designed Cool Safe compressors are specifi cally designed for low temperature applications 9 Multiple access ports permit inser tion of independent probes instru mentation or liquid N2 or liquid CO2 back up injectors 10 Commercially avai...

Страница 5: ...high impact polyurethane with newly developed foamed in place insulation and minimize exposure during routine door openings Dual inner door configuration stan dard with optional half inner door ac cessories available for field installation For a four door configuration order two sets of half inner doors A universal keyed door lock prevents the outer door from opening The two primary compartments c...

Страница 6: ...roughout the high and low stage circuits transmit information to the Panasonic Status Alert central controller for operation monitoring interpretation and component protection High Stage Capillary Tube Liquid refrigerant under pressure is passed through the capillary tube where it flash evaporates in the interstage heat exchanger to absorb energy heat from the low stage refrigerant circuit High St...

Страница 7: ...ed control overlay The panel is door mounted and angled for easy access Alarm indicator lamp glows when freezer is in alarm condition alarm ringback is factory set for 30 minutes adjustable in 10 minute increments from 10 to 60 minutes Panasonic exclusive Ni MH battery powers control memory and alarm functions during power failure Status alert function uses predictive intelligence to determine if ...

Страница 8: ...nergy manage ment to solar power and alternative energies Panasonic remains committed to providing the best possible labora tory equipment for research Uniformity Performance The placement of evaporator surfaces within the cabinet walls achieve excep tional documented ultra low temperature uniformity thereby permitting investiga tors more freedom in placing valuable cell lines and biologicals with...

Страница 9: ...er recirculation cooling systems This option utilizes the cascade refrig eration design to reuse the energy produced by an ultra low freezer while delivering energy savings and high performance cooling Ideal for material storage in repositories hospitals clinics and medical research facilities the water cooled system is designed to significantly reduce energy consumption Energy efficiency Cost sav...

Страница 10: ...ith locking rod SUMPR 612 LR SUMPR 612 LR SUMPR 612 LR 108 standard plates with cover lid per rack Capacity 6 Capacity 8 Capacity 24 R L 1 1 6 R P M U S d o r g n i k c o l h t i w s e t a l p o r c i m r o f k c a R y r o t n e v n I 8 y t i c a p a C k c a r r e p d i l r e v o c h t i w s e t a l p d r a d n a t s 6 9 Inventory Rack for microplates with locking rod SUMPR 616 LR 60 standard plat...

Страница 11: ...Cooled Option Features Description Water Pressure Temperature Maximum Water Pressure 150psig Minimum Water Pressure Differential 15psig Maximum Water Temperature 30 C Connections Typically compression fittings on inlet and outlet but can be customized for customer needs Required Water Flow Rate Maximum Tower Water 11 4 liters per minute Installation Qualified technician required at time of install...

Страница 12: ... 630 x 600 x 1380 mm 24 8 x 23 6 x 55 1 630 x 600 x 1400 mm 34 2 x 23 6 x 55 1 870 x 600 x 1400 mm 34 2 x 23 6 x 55 1 870 x 600 x 1400 mm Exterior w x f b x h 26 4 x 34 1 x 73 2 670 x 867 x 1860 mm 30 3 x 34 4 x 78 3 770 x 870 x 1990 mm 30 3 x 34 4 x 78 3 770 x 870 x 1990 mm 39 8 x 34 4 x 78 3 1010 x 870 x 1990 mm 39 8 x 34 4 x 78 3 1010 x 870 x 1990 mm Net Weight Empty 562 lbs 255 kg 660 lbs 299 ...